Hardware Reset
A recessed RESET button is provided for restoring the system to the
factory default settings. When the system fails to install properly, or
operates abnormally, use the RESET button located on the top panel of
the VPort 461A to restore the factory defaults.
To do this, use a pointed object such as a straightened paper clip or a
toothpick, to depress the reset button continuously for about 90 seconds.
Release the reset button when the STAT LED has finished the following
sequence twice: light-on light-off solid-red red-flash light-off.
At this point, the POST process will run, and the VPort will reboot. The
STAT LED will turn to green when the VPort has finished rebooting.
NOTE This device complies with part 15 of the FCC Rules. The operation
of the device is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device
must accept any interference received, including interference
that may cause undesired operation.
NOTE •
This equipment is intended for use in locations with restricted
access such as computer rooms. Access to the equipment
should be restricted to SERVICE PERSONS or USERS who are
trained and authorized to use this equipment. Furthermore,
access to the equipment should be restricted by the use of a
key, or a user identification system. Only authorized,
well-trained professionals should be given access to the
restricted area where the equipment is in operation.
•
External metal parts are HOT!!
Personnel who have access to this equipment should be
made aware of the hot surface of the equipment. They must
not touch the metal chassis of the equipment without proper
protection.
- 19 -