D-80
Programming
Operation
0-1 EDGE(A)
1-0 EDGE(A)
Description
input A
output
t
Duration: 1 block diagram cycle
Rising Edge Trigger
Input B is not used.
This function outputs a pulse of 5ms duration when INPUT A to the block becomes TRUE. When INPUT C is TRUE, the output
is inverted.
The output is held TRUE for one execution of the function block diagram.
input A
output
t
Duration: 1 block diagram cycle
Falling Edge Trigger
Input B is not used.
This function outputs a pulse of 20ms duration when INPUT A to the block becomes FALSE. When INPUT C is TRUE, the
output is inverted.
The output is held TRUE for one execution of the function block diagram.
input C FALSE
input C TRUE
input C FALSE
input C TRUE