8.4 Technical Data -
CS A Low Voltage Single Phase Units
Model:
CM12
Order Number: *
2 pole
1UA7053-2B[z]0.
4 pole
1UA7060-4B[z]0.
Frame size:
2 pole
56
4 pole
63
Motor Output
0.12kW
Rating:
0.16hp
Operating Input
Voltage:
Operating Input
Frequency:
Output
Frequency:
Output Frequency
with Opm2 or
serial link:
2 pole
0 – 100Hz
4 pole
0 – 140Hz
Input Current:
1.8 A
Mains fuse:
Mains Lead cross-
section
* [z] = filter option: U = Unfiltered, A = Class A filter, B = Class B filter.
Position 12 (shown as ".") is for the construction type from the Siemens catalogue, M11 (Ref. No.E2002-K1711-A201-A2-7600).
CS A Low Voltage Three Phase Units
Model:
CM12/2
Order Number: *
2 pole
1UA7053-2BU1.
4 pole
1UA7060-4BU1.
Frame size:
2 pole
56
4 pole
63
Motor Output
0.12kW
Rating:
0.16hp
Operating Input
Voltage:
Operating Input
Frequency:
Output Frequency:
Output Frequency
with Opm2 or
serial link:
2 pole
0 – 100Hz
4 pole
0 – 140Hz
Input Current:
1.1 A
Mains fuse:
Mains Lead cross-
section
* Note that these units are available Unfiltered only.
Position 12 (shown as ".") is for the construction type from the Siemens catalogue, M11 (Ref. No.E2002-K1711-A201-A2-7600).
Siemens plc. 1999
©
| G85139-H1731-U300-D2
COMBIMASTER
CM25
1UA7063-2B[z]0.
1UA7070-4B[z]0.
63
71
0.25kW
0.33hp
1∅ AC 208 – 240 V
0 – 100Hz
0 – 140Hz
3.2 A
rms
rms
10 A
2
1mm
CM25/2
1UA7063-2BU1.
1UA7070-4BU1.
63
71
0.25kW
0.33hp
3∅ AC 208 – 240 V
0 – 100Hz
0 – 140Hz
1.9 A
rms
rms
CM37
CM55
1UA7070-2B[z]0.
1UA7073-2B[z]0.
1UA7073-4B[z]0.
1UA7080-4B[z]0.
71
71
71
80
0.37kW
0.55kW
0.49hp
0.73hp
± 10%
rms
47 – 63 Hz
0 – 50Hz
0 – 100Hz
0 – 100Hz
0 – 140Hz
0 – 140Hz
4.6 A
6.2 A
rms
rms
CM37/2
CM55/2
1UA7070-2BU1.
1UA7073-2BU1.
1UA7073-4BU1.
1UA7080-4BU1.
71
71
71
80
0.37kW
0.55kW
0.49hp
0.73hp
± 10%
rms
47 – 63 Hz
0 – 50Hz
0 – 100Hz
0 – 100Hz
0 – 140Hz
0 – 140Hz
2.7 A
3.6 A
rms
rms
10 A
2
1mm
CM75
1UA7080-2B[z]0.
1UA7083-4B[z]0.
80
80
0.75kw
1.0hp
0 – 100Hz
0 – 140Hz
8.2 A
rms
16 A
2
1.5mm
CM75/2
1UA7080-2BU1.
1UA7083-4BU1.
80
80
0.75kw
1.0hp
0 – 100Hz
0 – 140Hz
4.7 A
rms
61