Parameter
P122
Enable/disable
FORWARD/REVERSE
button
P123
Enable/disable JOG
button
P124
Enable/disable ∆ and
∇ buttons
P125
Reverse direction
inhibit
P131
Frequency setpoint
(Hz)
P132
Motor current (A)
P133
Motor torque(%
nominal torque)
P134
DC link voltage (V)
P135
Motor RPM
P137
Output voltage (V)
P140
Most recent fault code
P141
Most recent fault code
-1
P142
Most recent fault code
-2
P143
Most recent fault code
-3
P151 • • • •
Green LED function
34
Function
Range
[Default]
0 - 1
[1]
0 - 1
[1]
0 - 1
[1]
0 - 1
[1]
0.0-fmax
[-]
0.0 - 99.9
[-]
0-250
[-]
0 - 1000
[-]
0 - 40000
[-]
0 - 1000
[-]
0 - 9999
[-]
0 - 9999
[-]
0 - 9999
[-]
0 - 9999
[-]
0 - 5
[4]
COMBIMASTER & MICROMASTER Integrated
Description / Notes
0 = FORWARD/REVERSE button disabled.
1 = FORWARD/REVERSE button enabled (only
possible if P007 = 1).
0 = JOG button disabled.
1 = JOG button enabled (only possible if P007=1).
0 = ∆ and ∇ buttons disabled.
1 = ∆ and ∇ buttons enabled (only possible if
= 1).
This applies for frequency adjustment only. The buttons can
still be used to change parameter values.
0 = Reverse direction disabled. Inhibits reverse
commands from ALL sources (reverse RUN
commands result in forward rotation)
1 = Normal operation (FORWARD/REVERSE
operation allowed)
Read-only parameters. These are copies of the values
selected by P001 but can be accessed directly via the
serial link.
The last recorded fault code (see section 5) is stored in this
parameter. It is cleared when the inverter is reset (P944 =1).
This is a copy of the code stored in P930.
This parameter stores the last recorded fault code prior to
that stored in P140/P930.
This parameter stores the last recorded fault code prior to
that stored in P141.
This parameter stores the last recorded fault code prior to
that stored in P142.
0 = Off
1 = On
2 = Fault mode:
On = Tripped
Flashing = Warning
3 = Running mode:
On = Motor running
Flashing = Inverter on but motor
stationary
4 = Default mode (see table in Operating Information,
Section 5).
5 = Not used
Siemens plc. 1999
©
REFERENCE MANUAL