Clack WS1 series Installation, Operation & Maintenance Manual

Clack WS1 series Installation, Operation & Maintenance Manual

Duplex water softeners

Advertisement

WS1", 1.5" & 2" Series Watersoftener
Installation Operation Maintenance Manual
Installation
Operation
Maintenance
Manual
Duplex Water Softeners
With WS1", 1.5" & 2" Series Valve
Models 20 ltr - 750 ltr

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WS1 series and is the answer not in the manual?

Questions and answers

Summary of Contents for Clack WS1 series

  • Page 1 WS1”, 1.5” & 2” Series Watersoftener Installation Operation Maintenance Manual Installation Operation Maintenance Manual Duplex Water Softeners With WS1”, 1.5” & 2” Series Valve Models 20 ltr - 750 ltr...
  • Page 2: Table Of Contents

    WS1”, 1.5” & 2” Series Watersoftener Installation Operation Maintenance Manual 1.0 PARTS LIST ....................3 1.1 BASIC PARTS LIST..................3 1.2 MISSING OR DAMAGED GOODS .............. 3 2.0 TEMPORARY STORAGE ................3 3.0 REGENERATION ..................3 3.1 The Regeneration Process ................. 3 3.2 METER CONTROL OF REGENERATION ..........
  • Page 3: Parts List

    WS1”, 1.5” & 2” Series Watersoftener Installation Operation Maintenance Manual 1.0 PARTS LIST 1.1 BASIC PARTS LIST 1. WS1 VALVE C/W TRANSFORMER 2. VESSEL & RISER 3. BRINE TANK 4. INSTRUCTIONS 5. REDUCER (if required) 6. RESIN 1.2 MISSING OR DAMAGED GOODS Immediately on receipt of the goods, it is advisable to check that all items ordered have been received.
  • Page 4: Meter Control Of Regeneration

    WS1”, 1.5” & 2” Series Watersoftener Installation Operation Maintenance Manual 4. Backwash (2nd) - This valve has the unique facility of performing a second backwash allowing for optimum regeneration, efficiency and cleaning of the resin bed. Water flows as in the first backwash cycle. 5.
  • Page 5: Operating Space

    WS1”, 1.5” & 2” Series Watersoftener Installation Operation Maintenance Manual 4.1.2 Operating Space The space occupied by the softener can be found in the Engineering Data (Section 11.2). Access will be required to refill the salt tank, and to carry out adjustments or maintenance on the equipment.
  • Page 6: Electrical

    WS1”, 1.5” & 2” Series Watersoftener Installation Operation Maintenance Manual 4.2 ELECTRICAL A continuous supply of 240v, 5 VA is required. The softener itself is 12 volt but a plug in 240v/12v transformer is supplied and should be connected to an uninterrupted mains supply, which is separately 1 Amp fused, and does not have any additional switch.
  • Page 7: Programming

    WS1”, 1.5” & 2” Series Watersoftener Installation Operation Maintenance Manual Unpack valve and skip down over the distributor tube. Screw the valve in to the resin vessel, taking care not to cross the threads. Excessive force should not be needed as the valve is running in to the vessel. Finally tighten to approximately 20 ft/lbs torque.
  • Page 8: Setting The Time Of Day

    WS1”, 1.5” & 2” Series Watersoftener Installation Operation Maintenance Manual 6.2.1 Setting the Time of Day 1. Press SET CLOCK The softener regeneration cycles have been factory programed. On metered softeners the volume capacity of the resin in litres has also been 2.
  • Page 9: Factory Programming

    WS1”, 1.5” & 2” Series Watersoftener Installation Operation Maintenance Manual regeneration has been entered as 2 AM, this can be changed if necessary. 6.3 Factory Programming Regeneration Programming (All programming below is Factory set) ↓ To alter settings – Press “↑” and “ ”...
  • Page 10 WS1”, 1.5” & 2” Series Watersoftener Installation Operation Maintenance Manual NEXT Capacity in Kilograms-Set according to Softener Size in Technical data if metered, ignore if timeclock NEXT Set Auto if metered, off if timeclock NEXT Set type of regeneration required:- “NORMAL”...
  • Page 11 WS1”, 1.5” & 2” Series Watersoftener Installation Operation Maintenance Manual Set effluent hardness in ppm if mixing valve fitted, if no mixing valve fitted then set to 0 if metered. NA if NEXT timeclock. Set day regeneration override for metered softeners OR set frequency of regenerations for Timeclock NEXT valves (1-28 days)
  • Page 12: Commisioning

    WS1”, 1.5” & 2” Series Watersoftener Installation Operation Maintenance Manual 7.0 COMMISIONING The objective of commisioning is to fill the softener and brine tank with water, check for leaks and prepare it for service. The simplest way to commission the unit is to initiate a regeneration. This will eliminate the air from the system and flush the resin prior to use.
  • Page 13 WS1”, 1.5” & 2” Series Watersoftener Installation Operation Maintenance Manual 7.1 Duplex Wiring One valve will be designated as Alt A (lead) and one as ALT B (lag). The Alt A valve has to be piped to the Alt A port of the Motorised Alternating Valve and the Alt B valve to the B Port on the Motorised Alternating Valve.
  • Page 14: Routine Monitoring

    WS1”, 1.5” & 2” Series Watersoftener Installation Operation Maintenance Manual NOTE 1 ½” picture shows old style Motorised Alternating Valve new style has the common outlet with water meter on the bottom port, Ports are labeled A, B and C. A always goes to Alt A, B to Alt B and C is Outlet.
  • Page 15: Fault Finding And Rectification

    WS1”, 1.5” & 2” Series Watersoftener Installation Operation Maintenance Manual 9.0 FAULT FINDING AND RECTIFICATION Modern water softeners are extremely reliable and unlikely to give any problems if they are installed and operated correctly. 9.1 NO FLOW TO SERVICE Check mains pressure is above 1.7 bar. Check inlet and outlet isolating valves are open.
  • Page 16: No Regeneration

    WS1”, 1.5” & 2” Series Watersoftener Installation Operation Maintenance Manual 9.3 NO REGENERATION Check electrical supply, fuses etc. satisfactory. Check control head motor runs by initiating a manual regeneration (Press “REGEN” button for 5s and then again for a further 5s), listening for drive motor ‘whirring' as it advances between cycles.
  • Page 17: Technical Data

    WS1”, 1.5” & 2” Series Watersoftener Installation Operation Maintenance Manual 11.0 Technical Data 11.1 Process and Operating Data 11.1.1 WS1 20-80 L PARAMETER UNITS MAX.SERVICE M3/hr FLOW SYSTEM CAPACITY 1.25 CaCO3 CAPACITY @ 13.3 300PPM SALT USED PER 11.2 REGEN REGENERATION TIME SALT STORAGE...
  • Page 18: Ws1 100-350 L

    WS1”, 1.5” & 2” Series Watersoftener Installation Operation Maintenance Manual 11.1.2 WS1 100-350 L PARAMETER UNITS 100L 120L 150L 250L 350L MAX.SERVICE M3/hr FLOW SYSTEM CAPACITY 12.5 17.5 CaCO3 CAPACITY @ 16.7 41.75 58.45 300PPM SALT USED PER 16.8 REGEN REGENERATION TIME SALT STORAGE...
  • Page 19: Ws1.5 100-500 L

    WS1”, 1.5” & 2” Series Watersoftener Installation Operation Maintenance Manual 11.1.3 WS1.5 100-500 L PARAMETER UNITS 100L 120L 150L 250L 350L 500L MAX.SERVICE M3/hr 11.6 11.6 FLOW SYSTEM CAPACITY 12.5 17.5 CaCO3 CAPACITY @ 16.7 41.75 58.45 83.5 300PPM SALT USED PER 16.8 REGEN REGENERATION...
  • Page 20: Ws2 150-750 L

    WS1”, 1.5” & 2” Series Watersoftener Installation Operation Maintenance Manual 11.1.4 WS2 150-750 L PARAMETER UNITS 150L 200L 250L 300L 350L 500L 750L MAX.SERVICE M3/hr FLOW SYSTEM 12.5 17.5 37.5 CAPACITY CaCO3 CAPACITY @ 33.4 41.75 50.1 58.45 83.5 125.2 300PPM SALT USED PER REGEN...
  • Page 21: Engineering Data

    WS1”, 1.5” & 2” Series Watersoftener Installation Operation Maintenance Manual 11.2 ENGINEERING DATA 11.2.1 WS1 20-80 L PARAMETER UNITS VESSEL SIZE INCH 9x35 10x35 10x44 10x54 12x48 13x54 BRINE TANK 1040 1040 1040 HEIGHT BRINE TANK WIDTH 370x TOTAL HEIGHT 1100 1100 1340...
  • Page 22: Ws1 100-350 L

    WS1”, 1.5” & 2” Series Watersoftener Installation Operation Maintenance Manual 11.2.2 WS1 100-350 L PARAMETER UNITS 100L 120L 150L 250L 350L VESSEL SIZE INCH 14x65 14x65 16x65 21x62 24x72 BRINE TANK 1040 1040 1100 HEIGHT BRINE TANK WIDTH TOTAL HEIGHT 1984 1984 1988...
  • Page 23: Ws1.5 100-500 L

    WS1”, 1.5” & 2” Series Watersoftener Installation Operation Maintenance Manual 11.2.3 WS1.5 100-500 L PARAMETER UNITS VESSEL SIZE INCH 14x65 14x65 16x65 21x62 24x72 30x72 BRINE TANK 1040 1040 1100 1250 HEIGHT BRINE TANK WIDTH 1250 TOTAL HEIGHT 1984 1984 1988 2038 2225...
  • Page 24: Ws2 150-750 L

    WS1”, 1.5” & 2” Series Watersoftener Installation Operation Maintenance Manual 11.2.4 WS2 150-750 L PARAMETER UNITS VESSEL SIZE INCH 16x65 21x62 21x62 24x72 24x72 30x72 36x72 BRINE TANK 1100 1100 1250 1250 1330 HEIGHT BRINE TANK 1050 WIDTH TOTAL 2098 2098 2098 2335...
  • Page 25: Factory Program

    WS1”, 1.5” & 2” Series Watersoftener Installation Operation Maintenance Manual 12.0 FACTORY PROGRAM To enter press Next and down for 5 seconds Screen Entered Value Explanation Softening Softening Valve 1 Backwash 25 4 Backwash time against resin 30 4 volumes 50 6 75 6 100 8...
  • Page 26 WS1”, 1.5” & 2” Series Watersoftener Installation Operation Maintenance Manual 100 14 120 16.8 150 21 or 6 for WS2 190 26.6 or 9 for WS2 250 35 or 13 for WS2 350 49 or 16 for WS2 500 70 or 26 for WS2 750 105 or 37 for WS2 Capacity 25 1.25...
  • Page 27: Ce Certificate

    Manufacturer's Declaration of Conformity We the undersigned EURAQUA UK, HITCHIN, ENGLAND Certify that the product type: SIMPLEX WATER SOFTENER WITH CLACK WS1, 1.5 or 2” 12 VOLT AC VALVE has been designed and manufactured in accordance with the specifications of the following:...

This manual is also suitable for:

Ws1.5 seriesWs2 series

Table of Contents

Save PDF