4. Every 100 hours operation, inspect fan belt for
condition and proper tension. Replace belt if condition
warrants. Check and adjust tension as follows:
A. Unlatch and raise hood and prop it open. Unlatch
and remove right side panel.
B. Proper tension will allow 1/2 in. (13 mm) deflection
when a force of 10 lb. is applied on the belt midway
between the pulleys. If deflection is incorrect,
proceed to step C; if deflection is correct, install
panel and close hood.
C. Loosen the 3 bolts securing alternator to plate and
mounting bracket (Fig. 43). Rotate alternator away
from engine to increase tension and tighten bolts.
Check belt tension after adjustment and re-adjust, if
necessary.
Figure 43
1. Alternator
D. Install panel and close hood.
5. Every 100 hours operation, check condition of cooling
system hoses and tightness of connections. Repair, as
needed.
6. Every 1000 hours, or yearly, drain and flush the cooling
system and replace the thermostat and hose assemblies.

Servicing the Air Cleaner

1. Check air cleaner body for damage which could
possibly cause an air leak. Replace a damaged air
cleaner body.
2. Service the air cleaner filter every 200 hours (more
frequently in extreme dusty or dirty conditions).
Removing the Filter
1. Release latches securing air cleaner cover to air cleaner
body (Fig. 44). Separate cover from body. Clean inside
of air cleaner cover.
1. Air cleaner latches
2. Gently slide filter out of air cleaner body to reduce the
1
amount of dust dislodged (Fig. 45). Avoid knocking
filter against air cleaner body.
1. Air cleaner filter
3. Inspect filter and discard if damaged. Do not wash or
reuse a damaged filter.