< M ain menu list of P A R - 30 M A A / P A R - 31 M A A >
S etting and disp lay items
V ane · L ouv er · V ent. ( L ossnay )
High p ower
T imer
O n/ O ff timer*
A uto- O ff timer
W eekly timer*
R estric tion
T emp . range
O p eration loc k
E nergy sav ing
A uto return
S c h edule*
N igh t setb ac k*
F ilter information
E rror information
M aintenanc e
A uto desc ending p anel A uto desc ending p anel ( O p tional p arts) U p / D own y ou c an do.
M anual v ane angle
I nitial setting
M ain/ S ub
C loc k
M ain disp lay
C ontrast
D isp lay details
A uto mode
A dministrator p assword
L anguage selec tion
S erv ic e
T est run
I np ut maintenanc e
F unc tion setting
C h ec k
S elf c h ec k
M aintenanc e p assword U se to c h ange th e maintenanc e p assword.
R emote c ontroller c h e c k W h en th e remote c ontroller does not work p rop erly , use th e remote c ontroller c h ec king func tion to trou-
OCH526C
U se to set th e v ane angle.
U se to turn O N / O F F th e louv er.
U se to set th e amount of v entilation.
U se to reac h th e c omfortab le room temp erature q uic kly .
U se to set th e op eration O n/ O ff times.
U se to set th e A uto- O ff time.
U se to set th e weekly op eration O n / O ff times.
U se to restric t th e p reset temp erature range.
U se to loc k selec ted func tions.
U se to get th e units to op erate at th e p reset temp erature after p erforming energy - sav e op eration for a
S et th e start/ stop times to op erate th e units in th e energy - sav e mode for eac h day of th e week, and set th e
energy - sav ing rate.
U se to make N igh t setb ac k settings.
U se to c h ec k error information wh en an error oc c urs.
W h en c onnec ting two remote c ontrollers, one of th em needs to b e designated as a sub c ontroller.
U se to set th e c urrent time.
U se to switc h b etween "F ull" and "B asic " modes for th e M ain disp lay .
U se to adj ust sc reen c ontrast.
M ake th e settings for th e remote c ontroller related items as nec essary .
C loc k:
T emp erature:
R oom temp . :
A uto mode:
W h eth er or not to use th e A uto mode c an b e selec ted b y using th e b utton.
T h is setting is v alid only wh en indoor units with th e A uto mode func tion are c onnec ted.
T h e administrator p assword is req uired to make th e settings for th e following items.
U se to selec t th e desired language.
S elec t "T est run" from th e S erv ic e menu to b ring up th e T est run menu.
S elec t "I np ut maintenanc e I nfo." from th e S erv ic e menu to b ring up th e M aintenanc e information sc reen.
T h e following settings c an b e made from th e M aintenanc e I nformation sc reen.
M ake th e settings for th e indoor unit func tions v ia th e remote c ontroller as nec essary .
E rror h istory :
R efrigerant leak c h ec k:
S mooth maintenanc e:
R eq uest c ode:
E rror h istory of eac h unit c an b e c h ec ked v ia th e remote c ontroller.
b lush oot th e p rob lem.
S etting details