3. Switch the connections between the guide wire
and the boundary wire in the charging station.
a) Switch connection AL and G1.
If the indicator lamp is lit with a solid green light,
then the break is somewhere on the boundary
wire between AL and the point where the guide
wire is connected to the boundary wire (thick black
line in the illustration).
b) Put AL and G1 back in their original positions.
Then switch AR and G1.
If the indicator lamp is lit with a solid green light,
then the break is somewhere on the boundary
wire between AR and the point where the guide
wire is connected to the boundary wire (thick black
line in the illustration).