Kits with telephone dialler
function
Voice - Dialler not responding to alarm
• Check the telephone line is connected and
that the correct telephone numbers have been
programmed.
• Ensure that an address message has been
recorded.
_____________________________________________
Faulty Situations
• In case any of the following faulty situations occur,
the yellow LED will light with a warning beep every
30 seconds (if switched on).
· Interference
· Tamper
· Radio Device Low Battery
· AC Power Fail
• A fault display will be show when the Arm or Home
Arm keys are pressed, with the device and fault
that is causing the problem.
• If more than one fault is present then individual
fault messages will be displayed sequentially at
2-second intervals.
_____________________________________________
Reset Procedure
Reset to factory default setting
The control panel can clear all programmed
parameters by the following sequence:
1 Power down control panel and remove the battery.
2 Apply power while holding down the p key.
3 Release the p key when a tone is heard, 'Enter
Code' will be displayed.
4 Enter the following key sequence:
pqpqpqpq ✓
5 Press the P key.
6 All programmed parameters are reset to factory
default setting.
7 If more than 17 incorrect keys are entered, then
the unit will revert to normal Alarm On mode.
Note
• Once the 'System Reset' is executed, all the
programmed data is return to its default value and
all the programmed devices will be removed.