Operation
10.
Deceleration
Turn the volume (frequency setting potentiometer)
counterclockwise slowly to full.
The frequency value on the indication decreases
according to Pr. 8 Deceleration time unitl "
(0.00Hz) is displayed and operation status indication
of FWD or REV flickers.
The motor stops.
11.
Stop
Press
.
Operation status indication of FWD (or REV)
turns off.
Change the frequency (50Hz) of the maximum value of potentiometer (at 5V)
Adjust the frequency in Pr. 125 Terminal 2 frequency setting gain frequency. (Refer to page 47.)
Change the frequency (0Hz) of the minimum value of potentiometer (at 0V)
Adjust the frequency in calibration parameter C2 Terminal 2 frequency setting bias frequency. (Refer to
Instruction Manual (applied).)
Start/stop from the operation panel (PU
Display
"
operation mode)
Flickering
Stop