8-3-2. Initial

Initial Failure

Check the CP Reset
(TP : RESET_PWRDWN_N) = 0V(LOW)
Check the CP active signal.
PDA_ACTIVE(TP_PDA_ACTIVE),
PHONE_ACTIVE(PHONE_ACTIVE)
Check the AP Reset
AP_N_RST_IN(R513) = 0V(LOW)
Check the oscillator clock waveforms.
32.768KHz : OSC500(TP213),
24Mhz : OSC400(C440)
Is the LCD display on?
Does the speaker make a sound?
Yes
Yes
>=
1.8V(HIGH)
Yes
Yes
Normal
Yes
Yes
END
SAMSUNG Proprietary-Contents may change without notice
This Document can not be used without Samsung's authorization
Check the UCP300 (short, crack, etc.)
No
※ Probing the Test point of UCP300
No
Check the UCP300 (short, crack, etc.)
※ Probing the Test point of UCP300
No
Check the U501 and R513 (crack, open, etc.)
Check the OSC500, OSC400 and R418.
(Crack, open etc.)
Abnormal
Check the output clock waveforms and frequency.
※ Test condition (Oscilloscope setting)
: 20.0us.div (time division)
No
Check the LCD part(short, crack, etc.)
No
Check the Audio Part(short, crack, etc.)