High-efficiency particle collection in- SPECIFICATIONS ......... E-15 cluding pollen and dust. Thank you for purchasing the SHARP Air Purifier. Please read this manual carefully for the correct usage information. Before using this product, be sure to read the section: “Important Safety In- structions.”...
• Use care when cleaning the air purifier. Strong corrosive cleansers may damage the exterior. • Only Sharp Authorized Servicers should service this air purifier. Contact the nearest Servicer for any problems, adjustments, or repairs.
• Follow the instructions in this manual for correct care and maintenance of the filters. HOW SHARP AIR PURIFIER WORKS An air purifier draws in room air from its air intake, lets the air pass through an Active Carbon Filter (Deodorizing Filter) and a HEPA Filter (dust collection filter) inside of the unit, then discharges the air from its air outlet.
PREPARATION INSERTING BATTERIES IN THE REMOTE CONTROL Remove the back cover Press and slide the back cover to remove. Insert batteries Insert batteries with shown below. Close the back cover Battery Information • The battery life is about 1 year. •...
PREPARATION Be sure to remove the power plug from the wall outlet. FILTER INSTALLATION To maintain the quality of the filters, they are installed in the main unit within plastic bags. Be sure to remove the filters from the plastic bags before using the unit. Remove the filters Remove the Front Panel.
Page 9
Tabs Install the filters Place the HEPA Filter HEPA Filter within the Filter Frame with the tabs facing up. Do not install the filter backwards or Filter Frame the unit will not operate properly. Place the Active Carbon Filter Band on top of the HEPA Filter Active Carbon Filter with the bands (2 places)
OPERATION Main Unit Controls • AUTO • 15 min. HIGH • POLLEN MAIN UNIT OPERATION • SILENT • NORMAL • MAX Plasmacluster Indicator Light Filter Indicator Light MODE Button Clean-Sign Light Power ON/OFF Button Power ON/OFF Button • Used to start operation (short beep) and stop operation (long beep) •...
DETERMINING THE BASE IMPURITY RATE For the first 30 seconds after the power plug is inserted into the wall outlet, the unit will check the conditions of the air. If operation is set to ON during this time, the CLEAN-SIGN LIGHT will alternately flash in green, orange and red. PLASMACLUSTER INDICATOR LIGHT Plasmacluster ion operation is selected using the remote control.
OPERATION Operations available with the Remote Control • AUTO • MANUAL REMOTE CONTROL OPERATION • POLLEN • OFF TIMER • 15 min. HIGH • DISPLAY ON/OFF Plasmacluster Ion mode selections POWER ON/OFF Button • AUTO • CLEAN • When you press the •...
CARE AND MAINTENANCE To maintain optimum performance of this air purifier, please clean the unit including the sensors and filters periodically. When cleaning the unit, be sure to unplug the power cord, and never handle the plug with wet hands. Electrical shock and/or bodily injury may occur as a result. MAIN UNIT To prevent dirt or stains on the main unit, clean as often as necessary.
CARE AND MAINTENANCE WASHABLE ACTIVE CARBON FILTER CARE Remove excess water HAND WASH ONLY! DO NOT TUMBLE DRY! The filter will be saturated with water after rins- ing. To decrease drying time, wrap the filter in Care Cycle an old thick towel so that excess water can be removed.
If dust or odors cannot be removed easily, replace the filters. (Refer to HOW SHARP AIR PURIFIER WORKS E-3) Guide for filter replacement timing • The following filter life and replacement period is based on the condition of smoking 10 cigarettes per day and the dust collection/deodorization power is reduced by half compared with that of new filters.
TROUBLESHOOTING Before calling for repair, please review the list below, since the problem may not be a unit malfunction. SYMPTOM REMEDY (not a malfunction) • Have the batteries been depleted? The Remote Control does not • Are the batteries inserted correctly? work •...
SPECIFICATIONS Model FU-P40S Power supply 220-240V 50/60Hz Fan speed level NORMAL SILENT 8.1 W Rated power 3.3 W 34 W Speed Operation 120 m /hour 30 m /hour Air Flow Volume 240 m /hour Applicable floor surface ~31m Cord Length 2.5m...