INTERFACE SPECIFICATIONS
ALARM STATUS SENSE(D5)
The external and video loss alarm states are indicated by a
6-byte response (see Table 2).
RXD
D5
TXD
d1
ALARM STATUS SENSE(D5) byte assignment
(Table 2)
First byte
Bit
7
ALARM ON 8
6
ALARM ON 7
5
ALARM ON 6
4
ALARM ON 5
3
ALARM ON 4
2
ALARM ON 3
1
ALARM ON 2
0
ALARM ON 1
Third byte
Bit
7
SENSOR 8
6
SENSOR 7
5
SENSOR 6
4
SENSOR 5
3
SENSOR 4
2
SENSOR 3
1
SENSOR 2
0
SENSOR 1
Fifth byte
Bit
7
VIDEO LOSS 8
6
VIDEO LOSS 7
5
VIDEO LOSS 6
4
VIDEO LOSS 5
3
VIDEO LOSS 4
2
VIDEO LOSS 3
1
VIDEO LOSS 2
0
VIDEO LOSS 1
English
d2
d3
d4
d5
d6
Second byte
Bit
7
6
5
4
3
2
1
0
ALARM ON 9
Fourth byte
Bit
7
6
5
4
3
2
1
0
SENSOR 9
Sixth byte
Bit
7
6
5
4
3
2
1
0
VIDEO LOSS 9
COMMANDS AVAILABLE FROM THE
MULTIPLEXER
ACK(0A)
Response when this unit receives a command.
NAK(0B)
Response if this unit did not receive the command.
ALARM(BF)
When there is an alarm, this command is sent as header. Then,
the alarm information is sent in a 1-byte transmission (see Table
3).
ALARM information (Table 3)
Bit
7
Alarm information
indication
6
5
Reserved
4
Reserved
3
Camera number
indication
2
1
0
51
Bit state information
00: No alarm
01: External
10: Video loss
11: Sensor alarm