28.2 Pre-Position Controls

R/D Function
Pre-position
Auto-pan left limit
Auto-pan right limit
Command lock mode activate
Command lock mode deactivate 104
Home Position
Move Pan position 180°
Erase record to end
Reset to factory defaults
Global Disable/Enable PP
Disable/Enable PP
NOTES
1. This setting stored with pre-position.
2. This setting stored as a default setting in non-volatile memory
(EEPROM) on R/D board and is used to restore settings at
power-up.
Default settings:
Autopan left limit = 0 degrees
Autopan right limit = 359.9 degrees
Autopan speed = 30 degrees per second
Auto-focus Activation = ON
Auto-iris Activation = ON
AutoSpeed = OFF
Spot auto-focus = OFF
Command Lock = OFF
Auto-shutter = OFF
Auto-Pivot Enabled (OFF)
Zoom Range Limit = OFF
Return Home = OFF
3.
This setting stored as a default setting in non-volatile
memory in camera.
Pre-Position #
Description
1-99
101
102
103
110
111, 180
500
erase playback to end
899
900
901-999
Set/Shot
set/show
set/show
set/show
set/---
set/---
recalibrate/show
---/show
set/---
set/---
disable/enable
disable/enable
4.
Pre-position #1 (if set) is automatically called-up upon
power-up just after the homing sequence.
5.
Scan direction determined by last manual pan direction.
6.
Pre-positions can be disabled such that they do not operate
during an automatic call-up (tour). They are still available for
manual call-up.
9.
This command clears all pre-positions, resets the EEPROMs
to factory defaults, and resets the lens and camera to defaults.
10. Access to certain AutoDome commands can be restricted
when using an Allegiant switching system. Allegiant system
operators with Priority levels 1 through 7 can activate the
'command lock' mode by 'setting' pre-position 103. Once
the lock mode is activated, Allegiant system operators with
priority level 8 would not be able to change functions
indicated by note 10. The higher priority operators (1-7) can
deactivate the 'command lock' mode by 'setting' pre-position
104.
11. Allegiant operators with priority level 8 are not permitted to
'set' pre-position functions.
65
Notes
4, 11
2, 11
2, 11
10, 11
10, 11
11
10
11
9, 11
10, 11
6, 10, 11