10. Service technicians should remove their 16. Always connect a test instrument's ground watches while repairing an MWO. lead to the instrument chassis ground before connecting the positive lead; always remove the instrument's ground lead last. Samsung Electronics...
Page 3
PRECAUTION with the oven energized. Servicemen should remove their watches whenever DO NOT measure the voltage in the high voltage circuit working close to or replacing the magnetron. including filament voltage of magnetron. Samsung Electronics...
2. Specifications 2-1 Table of Specifications MODEL MW6574W ITEM TIMER 99 MINUTES 99 SECONDS POWER SOURCE 220V/60HZ, AC POWER CONSUMPTION MICROWAVE : 1,500W OUTPUT POWER FROM 100W TO 1000W (10 LEVEL POWER) (IEC-705 TEST PROCEDURE) OPERATING FREQUENCY 2,450MHz MAGNETRON OM75PH(31)ESS...
Glass Tray Popcorn Diet Cook Minute Potoato Baby Food Frozen Fresh Dinner Vegetable Help Screen Custom Custom Auto Auto Defrost Reheat Power Level Clock Auto Start Hold Timer More Sound Less Pause Start Cancel 260mm 402mm 556mm 429mm Samsung Electronics...
4-2 Replacement of High Voltage Transformer 1. Discharge the high voltage capacitor. 2. Disconnect all the leads. 3. Remove the mounting bolts. 4. Reconnect the leads correctly and firmly. Bolts H. V. Trans Samsung Electronics...
1. Insertion depth of the thin metal plate should be 0.5mm or less. 4-3-4 Removal of Key Door & Spring Remove pin hinge from Door "E" Door "E" Detach spring from Door "E" and key door. Key Door Spring Samsung Electronics...
7. When replacing the drive motor, be sure to remount it in the correct position with the Drive Motor Cover Base Plate coupler. 8. Connect all the leads to the drive motor. 9. Screw the drive motor cover to the base plate with a screw driver. Samsung Electronics...
Page 9
3. When installing new membrane key board, make sure that the surface of escutcheon base is Membrane cleaned sufficiently so that any problems Panel (shorted contacts or uneven surface) can be avoided. Samsung Electronics...
5-1 High Voltage Transformer 1. Remove connectors from the transformer terminals Filament Terminals and check continuity. 2. Normal resistance readings are as follows: Primary Terminals MODEL MW6574W Secondary 75W ± 10% Filament Shows Continuity Primary 0.30W ± 10% (Room temperature = 20ûC)
Door Open Door Closed procedures. ¥ Primary switch 5. Confirm that the gap between the switch ¥ Monitor switch (COM-NC) housing and the switch actuator is no more than ¥ Door Sensing S/W 0.5mm when door is closed. Samsung Electronics...
Page 12
5. After heating for 2 minutes, measure the water temperature in each beaker. 6. Microwave heat distribution rate can be calculated as follows: Minimum Beaker Temperature Rise Heat Distribution = X 100(%) Maximum Temperature Rise The result should exceed 80%. Cooking Tray Samsung Electronics...
; CENTRAL SERVICE CENTER 5-13-2 At least once a year have the microwave energy survey meter checked for accuracy by its manufacturer. Samsung Electronics...
H.V.Transformer component test procedure and replace if it is H.V.Capacitor defective. H.V.Diode Magnetron 4. Open or loose wiring of power relay 5. Defective primary latch switch 6. Defective power relay or Ass'y PCB Replace PCB main. Samsung Electronics...
Page 15
Use plastic wrap or cover with a lid. Stir once or twice while cooking foods such as soup, cocoa, or milk. Noise from the turntable motor Noise may result from the motor. Replace turntable motor. when it starts to operate. Samsung Electronics...
FOR HIGH VOLTAGE LEADS OR AS NOTED ON SPECIAL LEADS. : P.C.B IN/OUT POINT MAGNETRON HIGH VOLTAGE DIODE TO CHASSIS PRIMARY SWITCH HIGH VOLTAGE CAPACITOR DOOR SENSING SWITCH MONITOR SWITCH BOTTOM CENTER SYMBOL COLOR ORANGE HIGH VOLTAGE WHITE TRANSFORMER BLACK BLUE POWER RELAY Samsung Electronics...