3104A007 Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. If you purchase the products from the sales agent of Huawei Technologies Co., Ltd., please contact our sales agent. If you purchase the products from Huawei Technologies Co., Ltd. directly, Please feel free to contact our local office, customer care center or company headquarters.
QoS/ACL, integrated management, STP, security and system management. Organization Quidway S2000-EI Series Ethernet Switches Installation Manual mainly introduces the hardware features, installation, configuration and maintenance of S2000 EI Series Ethernet Switches. To avoid any possible device damage and personal injury before the installation and during the installation, please read the manual carefully.
Page 5
Chapter 4 Powering on Switch for the First Time The chapter introduces the booting process of S2000-EI Series Ethernet Switches, including the power-on booting of the switch and the system initialization. Chapter 5 BootROM and Host Software Loading The chapter introduces several means to upgrade the software of S2000-EI Series Ethernet Switches.
Page 6
II. GUI conventions Convention Description Button names are inside angle brackets. For example, click the <OK> < > button. Window names, menu items, data table and field names are inside square brackets. For example, pop up the [New User] window. Multi-level menus are separated by forward slashes.
Page 7
Environmental Protection This product has been designed to comply with the requirements on environmental protection. For the proper storage, use and disposal of this product, national laws and regulations must be observed.
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 1 Product Overview Chapter 1 Product Overview 1.1 S2008-EI Ethernet Switch 1.1.1 Appearance Figure 1-1 S2008-EI Switch 1.1.2 Front View I. Front panel On S2008-EI front panel distribute one power LED (POWER), eight fixed...
Page 11
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 1 Product Overview (3) (4) (3) (4) (1) POWER LED (2) Eight fixed electrical ports (3) Port LED (left) (4) Port LED (right) (5) A/L mode LED (6) D/S mode LED (7) MODE button Figure 1-2 S2008-EI front panel II.
Page 12
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 1 Product Overview By toggling between the A/L and D/S mode LEDs using the MODE button, you can gather information about ACTIVE/LINK state and DUPLEX/SPEED using the port LEDs with reference to the following table:...
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 1 Product Overview 1.1.3 Rear View I. Rear panel On the S2008-EI rear panel distribute external power input and Console port (see the following figure): (1) Power input (2) Console port Figure 1-3 S2008-EI rear panel...
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 1 Product Overview 1.2 S2016-EI Ethernet Switch The S2016-EI Switch falls into two models: S2016-EI-AC and S2016-EI-DC. They differ only in the sense that the former is AC-powered and the latter is DC-powered.
Page 15
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 1 Product Overview (1) MODE button (2) D/S mode LED (3) A/L mode LED (4) PWR LED (5) 16 fixed electrical ports (6) Port LED (left) (7) Port LED (right) (8) Expansion slot...
Page 16
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 1 Product Overview Table 1-6 Port LEDs on S2016-EI front panel Status Port LED status Description mode LED Flashing (faster for heavier traffic, and nearly steady Traffic is being received or transmitted ON when the traffic is on the port.
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 1 Product Overview Table 1-8 Console port attributes Attribute Description Connector RJ-45 Port standard Asynchronous EIA/TIA-232 Baud rate 9600 (default) Connection to the ASCII terminal Connection to the serial port of a local terminal (which can be a PC) or a...
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 1 Product Overview 1.3 S2403H-EI Ethernet Switch The S2403H-EI Switch falls into two models: S2403H-EI-AC and S2403H-EI-DC. They differ only in the sense that the former is AC-powered and the latter is DC-powered.
Page 19
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 1 Product Overview II. LEDs on S2403H-EI front panel You can gather information about the status of the S2403H-EI and the ports using the LEDs on its front panel. Power LED Table 1-9 Power LED on S2403H-EI front panel...
Page 20
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 1 Product Overview Status Port LED status Description mode LED The port is in full duplex mode. Yellow (DUPLEX) The port is in half duplex mode. Flashing (at frequencies of mode The port operates at 100 Mbps...
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 1 Product Overview 1.3.3 Rear View I. S2403H-EI-AC rear panel (1) AC power socket (2) Grounding screw Figure 1-10 S2403H-EI-AC rear panel II. S2403H-EI-DC rear panel (1) DC power socket (2) Grounding screw Figure 1-11 S2403H-EI-DC rear panel 1.3.4 Optional Modules...
Page 22
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 1 Product Overview Item S2000-EI Series Ethernet Switches S2008-EI: 8 Number of fixed S2016-EI: 16 Ethernet port S2403H-EI: 25 Console port One Console port S2008-EI: 0 Number S2016-EI: 1 expansion slots S2403H-EI: 1...
Page 23
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 1 Product Overview Item S2000-EI Series Ethernet Switches S2008-EI uses external power supply. The input voltage and output voltage are as follows: Input rated voltage: 100 -- 240 V a.c.; 50/60 Hz Input maximum tolerance: 90 -- 264 V a.c.;...
Page 25
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 1 Product Overview Feature Functionality 802.1p and DSCP (Differentiated Services Codepoint Priority) preference bi-directional (outbound and inbound) port rate limitation, rate-limiting level ranges from 1 to 127. Suppose the level value is set to N. The rate at the port is N*64 kbps, where N is in the range 1 to 28 and 64 kbps is the granularity;...
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 2 Installation Preparation Chapter 2 Installation Preparation 2.1 Precautions To avoid any device impairment and bodily injury because of improper uses, please follow the precautions listed below: Before cleaning the switch, please unplug the switch connector first. Do not clean the switch with wet cloth or with liquid.
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 2 Installation Preparation 2.2.1 Temperature/Humidity Requirements To ensure the normal operation and service life of a switch, users need to maintain the temperature and the humidity of the equipment room at a certain level. If the humidity level in the equipment room is too high for a long time, it will lead to bad insulation of the insulating material or even leakage.
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 2 Installation Preparation Max. (mg/m 0.05 0.01 2.2.3 Anti-interference Requirements A switch in use may be affected by the interference sources outside the system in a way of capacitance coupling, inductance coupling, radiation of electromagnetic wave, common impedance (including the grounding system) or conducting line (power line, signaling line and transmission line etc.).
Page 29
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 2 Installation Preparation Caution: The installation tools are not shipped with S2000-EI Series Ethernet Switches. A user will have to prepare them beforehand.
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 3 Installation Chapter 3 Installation Caution: On a mounting screw of the chassis of any Quidway Series Switches, there is a seal which must be kept intact before the sales agent performs maintenance on the switch. The user must contact the local agent for permission before opening the chassis.
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 3 Installation (1) Magnet (2) Downward Figure 3-2 Installing a magnet piece into a bracket on the bottom of S2008-EI chassis Step 2: Mount S2008-EI onto the metal wall, ensuring the service ports facing downward vertically.
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 3 Installation 3.1.3 Mounting the S2008-EI on a Workbench S2008-EI is a small device that can be placed on a workbench or tabletop. You are recommended, however, to put rubber feet beneath the switch to protect it from being rubbed.
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 3 Installation Figure 3-4 Mounting the switch (into a 19-inch rack) Note: The mounting brackets are used for fixing rather than weight bearing. In a 19-inch standard rack, the weight of the switch is supported by the shelf beneath it.
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 3 Installation Neutral point Neutral point Live line Live line Zero line Zero line Figure 3-5 Recommended AC power socket II. Connecting AC power cord Step 1: Connect one end of the chassis ground wire to the grounding screw on the rear of the chassis and the other end to the ground as near as possible.
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 3 Installation Step 3: Check that the PWR LED on the front panel of the switch is ON. Caution: Before powering on the switch, connect the ground wire. 3.4.3 Connecting DC Power Cord (S2403H-EI-DC) (1) DC power input;...
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 3 Installation Caution: Before powering on the switch, connect the ground wire. 3.4.4 Connecting Ground Wire Caution: Correctly connect the switch ground wire, as it is crucial to the lightning protection and electromagnetic susceptibility (EMS) of a switch.
Page 37
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 3 Installation (1) Power input (2) Grounding screw (3) Ground wire (4) Grounding strip (5) Ethernet switch Figure 3-8 Grounding through a grounding strip When there is no grounding strip but earth near the equipment room that allows a grounding body to be buried, hammer an angle iron/steel pipe longer than 0.5...
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 3 Installation (1) AC power input (2) Grounding screw (3) Power transformer (4) PE wire (5) AC power input (with 3-wire cable) (6) Ethernet switch Figure 3-10 Grounding through AC PE wire For a DC-powered switch, if none of the first two conditions is available, ground it through the return wire (RTN) of the DC power supply.
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 3 Installation Figure 3-12 Console cable Table 3-1 Console cable pinouts RJ-45 Signal Direction DB-9 ← ← ← → ---- → → → 3.5.2 Connecting Console Cable Follow these steps to connect a terminal device, a PC for example, to the switch: Step 1: Plug the DB-9 female connector of the Console cable to the serial port of the PC where the switch is to be configured.
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 3 Installation Note: Serial ports on PCs do not support hot swap, meaning you cannot insert or remove a serial interface cable from a PC that is connected to a switch with power. In connecting/disconnecting a PC and a switch, always plug/unplug the DB9 connector of Console cable to/from the PC before plugging/unplugging the RJ45 connector to/from the switch.
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 3 Installation 3.6.2 Removing Optional Interface Module Follow these steps to remove an installed optional module: Step 1: Wear the ESD-preventative wrist strap and disconnect power of the switch. Step 2: Use the flat-blade screwdriver to unscrew the captive screws at both sides of the module.
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 4 Powering on Switch for the First Time Chapter 4 Powering on Switch for the First Time 4.1 Establish configuration environment Setting up the configuration environment (the following figure is as reference): Terminal (a PC in this example) is connected to the Console port of the switch through a Console cable.
Page 43
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 4 Powering on Switch for the First Time Parameter requirements: Set baud rate to 9600, data bit to 8, parity to none, stop bit to 1 and flow control to none. Select VT100 as terminal emulation. The specific...
Page 44
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 4 Powering on Switch for the First Time Figure 4-3 Setting the serial port to be used in HyperTerminal connection Click <OK> after the serial port is selected and the system will pop up the following interface.
Page 45
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 4 Powering on Switch for the First Time Figure 4-4 Setting serial port parameters Click <OK> when the serial port parameters are set and the system will enter the following interface. Figure 4-5 HyperTerminal...
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 4 Powering on Switch for the First Time Select [Properties] in the HyperTerminal dialog box to enter the property window. Click [Settings] in the property setting window as the following figure and select VT100 as the emulation terminal.
Page 47
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 4 Powering on Switch for the First Time Note: The boot display may change according to different switches. The display of S2403H-EI Switch is shown in the following example. Starting... ********************************************** Quidway S2403H-EI...
Page 48
<Quidway> By this time, a user can start configuring the switch. Note: Quidway series switches provide rich command modes. For introduction of the configuration commands and command line interfaces in detail, refer to Quidway S2000-EI Series Ethernet Switches Operation Manual.
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 5 BootROM and Host Software Loading Chapter 5 BootROM and Host Software Loading 5.1 Introduction to Loading Approaches This chapter introduces how to load BootROM and host software for a switch at the local and the remote.
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 5 BootROM and Host Software Loading 5.2.1 Boot Menu Take S2403H-EI Switch as an example. After being powered on, the switch runs the BootROM program first and displays the following information on the screen: Starting...
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 5 BootROM and Host Software Loading Input the correct BootROM password (by default, no password is set on the switch). The system enters the following Boot Menu: Caution: Please remember the BootROM password you have modified when using the switch.
Page 52
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 5 BootROM and Host Software Loading Enter your choice(0-5): Please set bootrom download protocol parameter: 1. Set TFTP protocol parameter 2. Set FTP protocol parameter 3. Set XMODEM protocol parameter 0. Return to boot menu Step 2: Press <3>...
Page 53
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 5 BootROM and Host Software Loading Figure 5-1 “Properties” dialog box Figure 5-2 “Console Port Configuration” dialog box...
Page 54
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 5 BootROM and Host Software Loading Step 6: Click <Disconnect> to disconnect the HyperTerminal from the switch and then click <Connect> to re-establish the connection, thus validating the baud rate setting. Figure 5-3 <Disconnect> and <Connect>...
Page 55
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 5 BootROM and Host Software Loading Figure 5-5 “Sending File” Interface After completing the loading, the system displays the following information: Loading ...CCCCCCCCCC done! ## Total Size = 0x00055d40 = 351552 Bytes Your baudrate should be set to 9600 bps again! Press enter key when ready.
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 5 BootROM and Host Software Loading 3. Set XMODEM protocol parameter 0. Return to boot menu← Enter your choice(0-3):3 The subsequent steps and those of loading BootROM are the same, except of the prompt messages.
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 5 BootROM and Host Software Loading Step 4: In the download protocol menu, press <1>to select TFTP protocol to download BootROM or host software. Press <Enter>. The system displays the following information: Load File name Switch IP address ←(This address and the IP address of the PC storing the files...
Page 58
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 5 BootROM and Host Software Loading II. Loading BootROM Step 1: Select an Ethernet port on the switch for loading and connect it to the PC storing the files to be downloaded. (You should know PC’s IP address). Besides, connect the switch to an external PC via Console port.
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 5 BootROM and Host Software Loading III. Loading host software Follow these steps to download the host software: Step 1: Select <1> in Boot Menu. The system displays the following information: 1. Set TFTP protocol parameter 2.
Huawei Technologies Co., Ltd. for help. 5.5 Dealing with Missing of Password Please contact the local agent of Huawei Technologies Co., Ltd. if the BootROM password or user password of the switch is lost.
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 6 Maintenance and Troubleshooting Chapter 6 Maintenance and Troubleshooting 6.1 Power System Failure You can check whether the power system of the switch fails by viewing the POWER indicator on the front panel. If it is in normal operation, the POWER indicator should stay on.
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 7 Optional Interface Modules Table 7-1 1Meaning of LEDs on 100Base-FX single-mode/multi-mode module panel Status description LINK OFF means the link is disconnected. ON means the line is connected. OFF means no data is being received or transmitted. Flashing means data is ACT or ACTIVE being received or transmitted.
Installation Manual Quidway S2000-EI Series Ethernet Switches Chapter 7 Optional Interface Modules Figure 7-3 1-port 100Base-T PoE interface module panel Table 7-3 Description of the LEDs on the 1-port 100Base-T PoE interface module panel Status description LINK OFF means the link is disconnected. ON means the link is connected.
Installation Manual Quidway S2000-EI Series Ethernet Switches Appendix A Lightning Protection of the Switch Appendix A Lightning Protection of the Switch A.1 Installation of Lightning Arrester for AC Power (Socket Strip with Lightning Protection) Caution: Lightning arrester will not be shipped with the switch. You should purchase it by yourself if needed.
Installation Manual Quidway S2000-EI Series Ethernet Switches Appendix A Lightning Protection of the Switch Caution: Make sure that the arrester is well grounded before using the lightning arrester for power. After inserting AC power cord plug of switch into the socket of lightning arrester, if the green LED is on and the red LED does not alarm, it means that the lightning arrester of power is running and the function of lightning protection has taken effect.
Page 69
Installation Manual Quidway S2000-EI Series Ethernet Switches Appendix A Lightning Protection of the Switch II. Installation procedure Step 1: Tear the protection paper at one side of the double faced adhesive tape apart from the tape, and stick the tape on the surface of the arrester. Tear the protection paper at another side apart from the tape, and stick the arrester onto the chassis of the switch.
Page 70
Installation Manual Quidway S2000-EI Series Ethernet Switches Appendix A Lightning Protection of the Switch III. Installation precautions Fully consider the following items in the installation process, otherwise, the performance of the lightning arrester for network port will be affected: Lightning arrester for network port is installed in reverse direction. In practice, the “IN”...