Installation and User Instructions
Aquarius Undersink Vented Water Heaters
Models: AU7/3, AU7/1, AU10/3, AU10/1
.
Please read and understand these instructions before starting work.
Please leave this leaflet with the user following installation
PACK CONTENTS
Heater, Fixing screws and plugs,
Installation and User Instructions, and
Guarantee card.
WARNING
This water heater must only be installed by
competent persons
36005806 Issue 08
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Aquarius AU7/3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Santon Aquarius AU7/3

  • Page 1 Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1 Please read and understand these instructions before starting work. Please leave this leaflet with the user following installation PACK CONTENTS Heater, Fixing screws and plugs, Installation and User Instructions, and Guarantee card.
  • Page 2: Technical Specification

    1.0 INTRODUCTION Thankyou for purchasing a Santon Aquarius water heater. The Aquarius water heater is manufactured in the UK to the highest standards and has been designed to meet all the latest relevant safety specifications. This Aquarius water heater must be installed and maintained by a competent person only.
  • Page 3: Installation

    3.1.2 The outlet of this water heater acts as a vent and must not be blocked or restricted in any way. 3.1.3 Only Santon open outlet accessories must be used with this water heater. A full range is available, please consult your distributor or Santon for further information.
  • Page 4 (see Figure 02). 3.2.2 Alternatively the heater can be connected directly to the water mains provided that a Santon ‘vented tap’ is used (see Figure 03). 3.2.3 Both inlet and outlet pipes are clearly labelled. The pipes are 15mm tube and are suitable for compression fittings.
  • Page 5 FIGURE 03: FIGURE 02: OPEN OUTLET APPLICATION CISTERN FED APPLICATION (USING 'VENTED TAP') CISTERN VENTED HOTT AP SINK MAINS STOP COCK COLD COLD STOP COCK MAINS FIGURE 04: INTERNAL LAYOUT CABLE CLAMP OUTLET THERMOSTAT CONTROL INLET CAPILLARY STAT TERMINAL BLOCK ELEMENT THERMAL CUT-OUT EARTH POST...
  • Page 6 Fault finding should only be carried out by a competent person and any replacement part should be authorised Santon spare parts. SYMPTOM PROBABLE CAUSE...
  • Page 7: Spare Parts

    Installation, and that all necessary controls and safety valves have been fitted correctly. 2. Any valves and controls are of the Santon recommended type and specification. 3. The unit has not been modified or tampered with in any way, and has been regularly maintained as detailed in the Installation and User Instructions.
  • Page 8: Spares Stockists

    Unit 1155 Aztec West, Almondsbury, Bristol BS32 4TF Tel: 01454 620500 Alternatively, contact your local supplying merchant, wholesale branch or use our online stockist finder at www.interpartspares.co.uk Service Tel: 0344 871 1530 Service E-mail: customer.support@heatraesadia.com Hurricane Way, Norwich Norfolk, NR6 6EA. www.santon.co.uk...

This manual is also suitable for:

Aquarius au10/1Aquarius au10/3Aquarius au7/1

Table of Contents