Service; Charging The Battery; Battery Removal - Cub Cadet Z-Force-S 48 Operator's Manual

Table of Contents

Advertisement

Available languages

Available languages

Service

WARNING!
the PTO switch in the "OFF" position, engage the
parking brake lever, turn the ignition key to the
"OFF" position and remove the key from the switch.

Battery Removal

WARNING!
accessories contain lead and lead compounds. Wash
hands after handling.
The battery is located beneath the seat box frame. To remove the
battery:
1.
Push down and back on the battery hold-down bracket as
shown in Fig. 7-1 to free it from the seat mount frame.
2.
Remove the hex cap screw and sems nut securing the black
negative battery lead to the negative battery post (marked
NEG). Move the cable away from the negative battery post.
3.
Remove the hex cap screw and sems nut securing the red
positive battery lead to the positive battery post (marked
POS).
4.
Carefully lift the battery out of the tractor.
5.
Install the battery by repeating the above steps in the
reverse order.
WARNING!
battery before connecting the negative lead. This
will prevent sparking or possible injury from an
electrical short caused by contacting the tractor
body with tools being used to connect the cables.
24
Before performing any service, place
Battery posts, terminals and related
Figure 7-1
Always connect the positive lead to the

Charging the Battery

Test and, if necessary, recharge the battery after the tractor has
been stored for a period of time.
A voltmeter or load tester should read 12.6 volts (DC) or
higher across the battery terminals. See Fig. 7-2.
Voltmeter
State of
Reading
Charge
12.7
100%
12.4
12.2
12.0
Figure 7-2
Charge the battery with a 12-volt battery charger at a
MAXIMUM rate of 10 amps.
Servicing Electrical System
A fuse is installed to protect the tractor's electrical system from
damage caused by excessive amperage. Always use the same
capacity fuse for replacement. If the electrical system does not
function, check for a blown fuse.
If you have a recurring problem with blown fuses, have the
tractor's electrical system checked by your Cub Cadet Service
Dealer.
Relays and Switches
There are several safety switches in the electrical system. If a
function of the safety interlock system described earlier is not
functioning properly, have the electrical system checked by your
Cub Cadet Service Dealer.
7
Charging
Time
Full Charge
75%
90 Min.
50%
180 Min.
25%
280 Min.

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents