General Faults
Malfunction
No display.
Shower will not operate.
No flow or low flow from
Shower Fittings.
Drip from showerhead.
Shower not hot enough.
Incorrect or fluctuating
temperature.
The batteries are flat or
incorrectly fitted.
Water supply isolated.
Flat batteries.
Electrical supply isolated or fuse
+
blown.
No connection to Digital Mixer.
+
Control out of range.
Digital Mixer malfunction.
Showerhead blocked.
Stuck Checkvalve in
Showerhead.
Hose blocked or twisted.
Digital Mixer malfunction.
"L" and or "H" values set too
low in Flow Range (F6).
A small amount of water may
be retained in showerhead after
showering. This may drain over
a few minutes.
Maximum showering
temperature set too low.
Digital Mixer fitted incorrectly.
Controller out of range.
Radio interference.
Warm up feature is being used
with combi-boiler.
Cause
22
Remedy
Check and rectify.
Check water supply.
Replace batteries.
Check electrical supply. If fuse
blown, replace Digital Mixer
Valve PCB.
Reset and recommission. Refer
to Installation Guide
Isolate electrical supply and
reset after 30 seconds
If problem persists, contact our
Customer Services Team.
Check and clean.
Check and clear or replace
Checkvalve.
Check and clean or release
twist.
Contact our Customer Services
Team.
Change to higher setting.
This is normal. Changing
position of showerhead may
vary draining time.
Increase maximum showering
temperature (Function F1).
Make sure hot and cold
water supplies are connected
correctly and delivering a
constant flow and temperature
within the required limits. See
"Specifications" in the "Mira
Platinum Installation Guide".
If problem persists, contact our
Customer Services Team.
Refer to "Fault Diagnosis" in
the "Digital Mixer Installation
Guide".
Need help?
Do you have a question about the Platinum and is the answer not in the manual?
Questions and answers