    CONTENTS Introduction ..................... 3 General ....................3 Safety Information ................... 3 Control Layout ..................4 Display Symbols ..................5 Using the Shower ..................6 Switch On/Off ..................6 Adjust Temperature ................7 Adjust Flow ................... 7 Functions ....................8 Function Menu ..................9 Enter the Function Menu ..............
  • Page 3: Introduction

    INTRODUCTION General Thank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take the time to read this guide thoroughly and keep it handy for future reference. The Mira Platinum Wireless Controller is a remote user interface and controls the following functions: •...
  • Page 4: Control Layout

    CONTROL LAYOUT Turn Outer Ring Showering Water Flow Adjustment Decrease Increase Flow Flow Decrease Increase Temperature Temperature Start/Stop Display...
  • Page 5: Display Symbols

    DISPLAY SYMBOLS Low Battery Display Economy Flow Display Temperature Display Flow Display Control Out Of Range Clock Display...
  • Page 6: Using The Shower

    USING THE SHOWER Switch On/Off Press “ ” to start or stop shower. Temperature and flow settings will be same as when last used. After a short period, display will dim to help extend battery life. Approximately 10 minutes after shower has stopped, display will turn off automatically. Shower will not run continuously for more than 30 minutes before stopping automatically (5 minutes when “ECO”...
  • Page 7: Adjust Temperature

    Adjust Temperature While shower is running, press “ + ” or “ - ” to adjust temperature. Showering temperature appears on display in degrees Celsius (°C). Adjust Flow Turn outer ring clockwise or anticlockwise to adjust flow. Showering flow level appears on display in white bars.
  • Page 8: Functions

    FUNCTIONS The following functions can be altered individually to adjust how the shower operates: F1 - Maximum Showering Water Temperature. This is the temperature the shower cannot go beyond when in use. F2 - Eco. The shower will stop automatically after 5 minutes.
  • Page 9: Function Menu

    FUNCTION MENU Enter the Function Menu Press “+” and “ ” buttons simultaneously until “End” is displayed on the unit. U s e “ + ” o r “ - ” b u t t o n s t o c y c l e t h r o u g h f u n c t i o n s a n d p r e s s “...
  • Page 10: Exit The Function Menu

    Exit the Function Menu When finished, use “+” or “-” buttons to cycle back through functions until “End” appears. Press “ ” to exit. Control is ready to use. If necessary, test shower to see if functions are working as expected.
  • Page 11: Changing Functions/Settings

    CHANGING FUNCTIONS/SETTINGS Maximum Showering Water Temperature Factory default “45°C”. Cycle menu to “F 1” and press “ ”. Press “+” or “-” to adjust temperature. Maximum = 48°C Minimum = 35°C Press “ ” to set. Press “ ” to exit back to Function Menu.
  • Page 12: Eco

    Factory default “off”. Cycle menu to “F 2” and press “ ”. Press “+” or “-” to change setting “on” or “off”. Press “ ” to set. Press “ ” to exit back to Function Menu. See section “Exit the Function Menu”.
  • Page 13: Warm-Up

    Warm-Up Factory default “off”. Note! Function will not work with combination boilers. Cycle menu to “F 3” and press “ ”. Press “+” or “-” to change setting “on” or “off”. Press “ ” to set. Press “ ” to exit back to Function Menu.
  • Page 14 Clock Setting Factory default “4:00”. Note! Can also be activated by disconnecting and reconnecting battery. Cycle menu to “F 4” and press “ ”. Press “-” to change hour setting. Press “+” to change minute setting. Press “ ” to set time and exit back to Function Menu.
  • Page 15: Clock Display

    Clock Display Factory default “on”. Cycle menu to “F 5” and press “ ”. Press “+” or “-” to change setting “on” or “off”. Press “ ” to set. Press “ ” to exit back to Function Menu. See section “Exit the Function Menu”.
  • Page 16: Flow Range

    Flow Range For use with High Pressure/Combi Valve version only. Factory default “1 - 99” Cycle menu to “F 6” and press “ ”. “on” is displayed, press “ ” to start shower. L o w e r l i m i t i s d i s p l a y e d , e . g . “L 1”. Adjust flow to desired lower limit 1-99.
  • Page 17 H i g h e r l i m i t i s d i s p l a y e d , e . g . “H 23”. Adjust flow to desired higher limit 1-99. (Most plumbing systems may achieve maximum flow before 99.) Press “...
  • Page 18: Control Frequency

    Control Frequency Factory default “1”. Cycle menu to “F 7” and press “ ”. Press “+” or “-” to change channel “1-7”. Press “ ” to set. Press “ ” to exit back to Function Menu. See section “Exit the Function Menu”.
  • Page 19: Replacing The Batteries

    REPLACING THE BATTERIES To access the batteries, the control unit must be removed from the wall. Make sure control unit is dry before removing. Press button to release and remove control from wall. Turn unit over to access batteries. Remove and replace all batteries. Only use new batteries of same make and type.
  • Page 20: Fault Diagnosis

    4. If shower operation does not return to normal, check the water supplies to the valve are within the correct temperature and pressure ranges. See “Mira Platinum Installation Guide - Specifications”. 5. If problem still occurs, make a note of the error code and contact our Customer Services Team.
  • Page 21 Control Sensor or PCB Relay 1. Turn Digital Mixer off for 15 seconds. Turn back on and allow 15 seconds to reset. 2. If shower operation does not return to normal, replace Thermistor. (To be performed by competent tradesperson only!) 3.
  • Page 22: Troubleshooting

    Make sure hot and cold Digital Mixer fitted incorrectly. water supplies are connected correctly and delivering a constant flow and temperature within the required limits. See “Specifications” in the “Mira Platinum Installation Guide”. If problem persists, contact our Customer Services Team. Incorrect or fluctuating Controller out of range.
  • Page 23 Fluctuating or reduced flow. Filters blocked. Refer to “Fault Diagnosis” in the “Digital Mixer Installation Water pressure too low. Guide”. Flow rate is too low. Fluctuating water temperature. Maximum blend temperature Incorrect maximum Refer to “Maximum Shower too hot or too cold. temperature setting. Water Temperature”...
  • Page 24: Cleaning

    CLEANING Many household cleaners contain abrasives and chemical substances, and should not be used for cleaning chrome plated or plastic fittings. These finishes should be cleaned with a mild washing up detergent or soap solution, and then wiped dry using a soft cloth. DISPOSAL AND RECYCLING End of Product Life When the appliance has reached the end of its serviceable life, it should be disposed of in a safe manner and in accordance with current local authority recycling or waste disposal policy.