CONTENTS Introduction ..................... 3 General ....................3 Safety Information ................... 3 Control Layout ..................4 Display Symbols ..................5 Using the Shower ..................6 Switch On/Off ..................6 Adjust Temperature ................7 Adjust Flow ................... 7 Functions ....................8 Function Menu ..................9 Enter the Function Menu ..............
INTRODUCTION General Thank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take the time to read this guide thoroughly and keep it handy for future reference. The Mira Platinum Wireless Controller is a remote user interface and controls the following functions: •...
CONTROL LAYOUT Turn Outer Ring Showering Water Flow Adjustment Decrease Increase Flow Flow Decrease Increase Temperature Temperature Start/Stop Display...
USING THE SHOWER Switch On/Off Press “ ” to start or stop shower. Temperature and flow settings will be same as when last used. After a short period, display will dim to help extend battery life. Approximately 10 minutes after shower has stopped, display will turn off automatically. Shower will not run continuously for more than 30 minutes before stopping automatically (5 minutes when “ECO”...
Adjust Temperature While shower is running, press “ + ” or “ - ” to adjust temperature. Showering temperature appears on display in degrees Celsius (°C). Adjust Flow Turn outer ring clockwise or anticlockwise to adjust flow. Showering flow level appears on display in white bars.
FUNCTIONS The following functions can be altered individually to adjust how the shower operates: F1 - Maximum Showering Water Temperature. This is the temperature the shower cannot go beyond when in use. F2 - Eco. The shower will stop automatically after 5 minutes.
FUNCTION MENU Enter the Function Menu Press “+” and “ ” buttons simultaneously until “End” is displayed on the unit. U s e “ + ” o r “ - ” b u t t o n s t o c y c l e t h r o u g h f u n c t i o n s a n d p r e s s “...
Exit the Function Menu When finished, use “+” or “-” buttons to cycle back through functions until “End” appears. Press “ ” to exit. Control is ready to use. If necessary, test shower to see if functions are working as expected.
CHANGING FUNCTIONS/SETTINGS Maximum Showering Water Temperature Factory default “45°C”. Cycle menu to “F 1” and press “ ”. Press “+” or “-” to adjust temperature. Maximum = 48°C Minimum = 35°C Press “ ” to set. Press “ ” to exit back to Function Menu.
Factory default “off”. Cycle menu to “F 2” and press “ ”. Press “+” or “-” to change setting “on” or “off”. Press “ ” to set. Press “ ” to exit back to Function Menu. See section “Exit the Function Menu”.
Warm-Up Factory default “off”. Note! Function will not work with combination boilers. Cycle menu to “F 3” and press “ ”. Press “+” or “-” to change setting “on” or “off”. Press “ ” to set. Press “ ” to exit back to Function Menu.
Page 14
Clock Setting Factory default “4:00”. Note! Can also be activated by disconnecting and reconnecting battery. Cycle menu to “F 4” and press “ ”. Press “-” to change hour setting. Press “+” to change minute setting. Press “ ” to set time and exit back to Function Menu.
Clock Display Factory default “on”. Cycle menu to “F 5” and press “ ”. Press “+” or “-” to change setting “on” or “off”. Press “ ” to set. Press “ ” to exit back to Function Menu. See section “Exit the Function Menu”.
Flow Range For use with High Pressure/Combi Valve version only. Factory default “1 - 99” Cycle menu to “F 6” and press “ ”. “on” is displayed, press “ ” to start shower. L o w e r l i m i t i s d i s p l a y e d , e . g . “L 1”. Adjust flow to desired lower limit 1-99.
Page 17
H i g h e r l i m i t i s d i s p l a y e d , e . g . “H 23”. Adjust flow to desired higher limit 1-99. (Most plumbing systems may achieve maximum flow before 99.) Press “...
Control Frequency Factory default “1”. Cycle menu to “F 7” and press “ ”. Press “+” or “-” to change channel “1-7”. Press “ ” to set. Press “ ” to exit back to Function Menu. See section “Exit the Function Menu”.
REPLACING THE BATTERIES To access the batteries, the control unit must be removed from the wall. Make sure control unit is dry before removing. Press button to release and remove control from wall. Turn unit over to access batteries. Remove and replace all batteries. Only use new batteries of same make and type.
4. If shower operation does not return to normal, check the water supplies to the valve are within the correct temperature and pressure ranges. See “Mira Platinum Installation Guide - Specifications”. 5. If problem still occurs, make a note of the error code and contact our Customer Services Team.
Page 21
Control Sensor or PCB Relay 1. Turn Digital Mixer off for 15 seconds. Turn back on and allow 15 seconds to reset. 2. If shower operation does not return to normal, replace Thermistor. (To be performed by competent tradesperson only!) 3.
Make sure hot and cold Digital Mixer fitted incorrectly. water supplies are connected correctly and delivering a constant flow and temperature within the required limits. See “Specifications” in the “Mira Platinum Installation Guide”. If problem persists, contact our Customer Services Team. Incorrect or fluctuating Controller out of range.
Page 23
Fluctuating or reduced flow. Filters blocked. Refer to “Fault Diagnosis” in the “Digital Mixer Installation Water pressure too low. Guide”. Flow rate is too low. Fluctuating water temperature. Maximum blend temperature Incorrect maximum Refer to “Maximum Shower too hot or too cold. temperature setting. Water Temperature”...
CLEANING Many household cleaners contain abrasives and chemical substances, and should not be used for cleaning chrome plated or plastic fittings. These finishes should be cleaned with a mild washing up detergent or soap solution, and then wiped dry using a soft cloth. DISPOSAL AND RECYCLING End of Product Life When the appliance has reached the end of its serviceable life, it should be disposed of in a safe manner and in accordance with current local authority recycling or waste disposal policy.
E-mail: technical@mirashowers.com with the requirements of the TMV 2 or TMV 3 healthcare Fax: 01242 282595 schemes. By Post: Mira Customer Services Dept, Cromwell Road, Products purchased ex-showroom display. Cheltenham, Gloucestershire, GL52 5EP What to do if something goes wrong...
Need help?
Do you have a question about the Platinum and is the answer not in the manual?