Separate primary AC power and standby battery wires from all power-limited wiring. Refer to
Section 7.2 Power-limited Wire Routing on page 58 for more information.
2.7.1

Programmable Output 1 Wiring

Switched 12 V Option
1
2
(+) (-)
3
Warning device (without battery)
1 - Programmable Output 1 (PO 1)
2 - Jumper plug position for switched 12 V option
3 - Warning device
Switched Ground Position
1 - Programmable Output 1 (PO 1)
2 - Jumper plug position for switched ground option
3 - Control panel board white auxiliary power terminals (12 VDC)
4 - Warning device
16
4
Warning device (with battery)
1 - Programmable Output 1 (PO 1)
2 - Jumper plug position for switched 12 V option
3 - Control panel board white auxiliary power
4 - Warning device
5 - Warning device activates when trigger voltage
3
2
1
(+)
(-)
4
1
2
3
(+)
(-)
5
+ -
terminals (12 VDC)
is removed