Siemens SICHARGE UC 150 UL Installation And Operation Manual page 99

Plug-in dispenser
Table of Contents

Advertisement

Description
Startup_Sequencer_Failure
Stop_Sequencer_Failure
SinePower: Input_Main_Low_Error
SinePower: Input_Contactor_OFF_Error
SinePower: Over_Temperature_Error
SinePower: Output_Short_Circuit_Error
SinePower: Output_Overload_Error
SinePower: Input_Mains_High_Error
SinePower: DC_Link_Under_Voltge_Error
SinePower: Retifier_IGBT_Desaturation_Error
SinePower: Input_Mains_Current_Error
SinePower: Shutdown_Rectifier_Error
SinePower: Inverter_IGBT_Desaturation_Error
SinePower: DC_BUS_Pre_Charge_Timeout_Error
SinePower: DC_Link_Over_Voltage_Error
SinePower: DC_Link_Under_Balance_Error
SinePower: Output_Over_Voltage_Error
SinePower: Output_Under_Voltage_Error
SinePower: Start_Timeout_Error
SinePower: Frequency_Deviation_Error
Installation and Operations Manual | SICHARGE UC 150 UL Plug-in Dispenser
Error
Error
Code
Handling
73
Check that K2 briefly closes on start up
Check that K1 closes on start up
Measure resistance of RBD1, RBD2 and RBD3
Restart startup sequence
74
Check if K11 and K12 have opened after a stopped session
Check if the sinepower board turned off after a charge session
Check if K1 turned off after a charge session
Ensure that the AC capacitors have discharged
75
Measure the level of the input voltage at the AC input breaker
Measure the AC input voltage on the SinePower board
Measure the artifical netural on the SinePower board
Measure the resistance of RY1 and RY2
76
Check K1 feedback wire for a broken wire or loose connection
77
Ensure that all fans are running
78
Measure the resistance between the DC output
79
Requested output voltage and current is too high
80
Measure the level of the input voltage at the AC input breaker
Measure the AC input voltage on the SinePower board
Measure the artifical netural on the SinePower board
Measure the resistance of RY1 and RY2
Turn breaker CB3 off and on
81
Measure each bus for a balanced voltage
Turn breaker CB3 off and on
82
Check for a short circuit on IGBT output
Turn breaker CB3 off and on
83
Check for a short circuit on the AC input panel
Turn breaker CB3 off and on
84
Check rectifier for a broken wire or a loose connection
Check each nut for a proper torque
Turn breaker CB3 off and on
85
Check for a short circuit on IGBT output
Turn breaker CB3 off and on
86
No longer monitored by SinePower
Turn breaker CB3 off and on
87
Measure each bus for a balanced voltage
Turn breaker CB3 off and on
88
Measure each bus for a balanced voltage
Turn breaker CB3 off and on
89
Measure AC input voltage. Voltage should not exceed 10% of speci-
fied AC input voltage
Turn breaker CB3 off and on
90
Measure AC input voltage. Voltage should not exceed 10% of
specified AC input voltage
Turn breaker CB3 off and on
91
Turn breaker CB3 off and on
92
Measure the frequency of the alternating current
The charging station is set to an input frequency of 50/60 Hz ±10%
OCPP Error
Category
InternalError
InternalError
Undervoltage
PowerSwitchFailure
HighTemperature
InternalError
Overvoltage
Overvoltage
Undervoltage
InternalError
OverCurrentFailure
InternalError
InternalError
InternalError
Overvoltage
OtherError
Overvoltage
Undervoltage
InternalError
OtherError
99