Manual Control PID
The following figure shows the Manual Control PID for controlling the selected SICHARGE UC dispenser.
Dispenser Number
a
Switch for automatic or manual test charging procedure
s
Switch for DC converter manual
d
Switch for manual output contactor
f
Switch for engaging fast discharge of DC output
g
Setpoint for fast discharge in seconds (defaults to 2 seconds)
h
Countdown timer to selected fast discharge setting
j
Setpoint for voltage and current
k
Status lights for main contactor, output (+/-) and discharge resistor
l
Home button
;
Figure 8-16 Manual Control PID