Connection Of Inductive Proximity Switch - Bosch CRS 845 Installation Instructions Manual

Common rail test-equipment set
Hide thumbs Also See for CRS 845:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 15
4.2

Connection of inductive proximity switch

Sequence:
1.
Pull the connecting cables of the inductive proximity switches
B11 and B12 through the distributor box's X10 screwed
cable connection.
2.
Join the connecting lines. To do so, use the following Fig. 22
and terminal diagram.
3.
After contacting the connecting lines, pull the screwed cable
connection on the distributor box.
EPS
X10
458777-22
Fig. 22
B11-B13
Inductive proximity switch
X10
Distributor box
Terminal diagram
A10
X14
2
3
4
1
5
1
2
3
4
5
1
2
3
4
5
6
1
2
3
4
5
6
X10
1
2
3
4
5
6
1
+
-
+
-
+
B11
B12
B13
22
B11 B12
B13
A10
Control device
X14
Connecting line
X10
Distributor box
B11 Induct. sensor
(drive side)
B12 Induct. sensor
B13 Induct. sensor
(Front side)
7
8
9
7
8
9
2
3
-
4.
Join connecting line X14 from the control device to the X10.1
connector of the connecting box X10.
5.
Join connecting line from the inductive proximity switch B13
to the X10.2 connector of the connecting box.
6.
Route all connecting lines into the cable ducts in the longitu-
dinal member and on the side frame.
B13
Fig. 23
X10.2
X10.1
X14 X10

Advertisement

Table of Contents
loading

This manual is also suitable for:

1 687 001 845