Eoi Remote Mounting - Toshiba ACE-tronics G9 ASD Installation And Operation Manual

Adjustable speed drive
Hide thumbs Also See for ACE-tronics G9 ASD:
Table of Contents

Advertisement

EOI Remote Mounting

The ASD may be controlled from a remotely-mounted EOI. For safety and application-specific reasons,
some ASD installations will warrant that the operator not be in the vicinity during operation or that the
EOI not be attached to the ASD housing. The EOI may be mounted either with or without the optional
Remote Mounting Kit (P/N ASD-MTG-KIT). The ease of installation is enhanced by the Remote
Mounting Kit (P/N 58333) which allows for EOI placement and easier cable routing.
Remote mounting will also allow for multiple EOI mountings at one location if controlling and
monitoring several ASDs from a central location is required.
The EOI can operate up to nine feet away from the ASD. A EOI extender cable is required for remote
mounting. The EOI extender cable is available in a nine-foot length and may be ordered through the ACE
World Companies Customer Support Center.
The optional dust cover (P/N ASD-BPC) may be used to cover the front panel opening of the ASD
housing after removing the EOI.
Remote EOI Required Hardware
EOI Mounting Hardware
EOI Remote-Mount Housing — P/N 58333 (included with 230-volt 40-HP and above; and with the
460-volt 75 HP and above)
6-32 x 5/16" Pan Head Screw — P/N 50595 (4 ea.)
#6 Split-Lock Washer — P/N 01884 (4 ea.)
#6 Flat Washer — P/N 01885 (4 ea.)
Bezel Plate Mounting Hardware
Bezel Plate — P/N 52291
10-32 Hex Nut — P/N 01922 (4 ea.)
#10 Split-Lock Washer — P/N 01923 (4 ea.)
#10 Flat Washer — P/N 01924 (4 ea.)
Dust Cover — P/N ASD-BPC (Optional)
Extender Cable
ASD-CAB10F: Cable, 9 ft.
EOI Installation Precautions
Install the unit securely in a well ventilated area that is out of direct sunlight using the four mounting holes
at the rear of the EOI. The ambient temperature rating for the EOI is 14° to 104° F (-10° to 40° C).
Select a mounting location that is easily accessible by the user.
Avoid installation in areas where vibration, heat, humidity, dust, metal particles, or high levels of
electrical noise (EMI) are present.
Do not install the EOI where it may be exposed to flammable chemicals or gases, water, solvents, or
other fluids.
Turn on the power only after securing the front cover of the ASD.