ERROR
CODE
E903
No specified 2D code pattern.
E910
Existed invalid character for converting into bar code.
E911
Cannot create bar code.
Too small dimension of narrow element/basic module
E912
width for bar code.
E913
No quiet zone in bar code.
E914
Too small separate pattern or composite row height.
Reference
• When other error not listed in this section was occurred, restart the laser marker.
• If the symptom persists after restart, contact our sales office.
Error details
ME-LP400V-OP-6
Measures
Specify 2D pattern code which has been already
registered.
Set the character that can be bar coded.
Use the condition where a barcode can be created.
Specify the setting value for the width of the narrow
element/basic module larger than that of the line
width of the laser.
Set the proper value for "Quiet/Narrow Ratio".
With the inversion setting, set always quiet zone.
• Adjust the height of one step bar code.
• Specify the proper value for "Separation Ptrn H/W"
so that the "Separation Pattern Height" becomes
"0" or "Marking Width" is larger than "Separation
Pattern Width".
307