Step 1: Enable SMDI
1. Select the appropriate Strata DK system with SMDI integration from the Toshiba Plug and Play
screen. (See
"Toshiba Plug and Play" on page 4-4
2. Define parameters in Stratagy System Configuration for SMDI/Serial Integration (see
4-4).
3. Define the Serial Ports used for the link (see
4. Define Message Notification via SMDI in the Notify table of each mailbox. The
used to send the proper commands for enabling and disabling Message Waiting over the serial
port of the Stratagy. A number of default templates can be found in the Template table that
works with most SMDI applications. (See
Example titles of the SMDI templates are:
COM1-3D LGHT On
COM1-3D LGHT Off
Where:
COM1 defines the COM port used as 1, and 3D defines the digit length of the User ID as 3.
Note
By selecting the template, the token programming sequence, starting with the
placed automatically by Stratagy in the Notify Menu's Method field. To prevent Stratagy
from physically taking a port off-hook, you must place an "@" sign before the
in the field.
Table 4-4
SMDI Parameters
Parameter
smdi_base_port
smdi_port
smdi_pretimeout
smdi_type
Stratagy I&M
06/02
page
"Templates" on page
Some SMDI installations use logical terminal numbers that do not begin with 1 (for
example, if it uses the extension or physical number to define the terminal). In these
situations, you must define the extension number where port 1 is connected. The
system assumes that the extension numbers are then connected in numerical order
to the remaining ports.
Example: 208 (extension number of port in Strata DK)
Default: 1
Logical serial port Stratagy uses for SMDI integration.
Possible values: 0 (disables SMDI integration), 1, 2 (port number)
Default: 0
Maximum number of seconds that an SMDI packet can precede the forwarded call.
Possible values: 5~50 (seconds)
Default: 50
Protocol Stratagy uses with RS-232 data integration (outband integration).
'smdi':
standard SMDI integration
's75':
System 75 integration
Possible values: 'smdi', 's75' The single quotes are required.
Default: 'smdi'
for instructions.)
4-28). Strata DK settings are: 7, even, 1 stop.
6-28.)
Description
Configure Stratagy
SMDI Serial Integration
Table
S( )
token is
token, is
S( )
token
S( )
4-33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Stratagy flashSg-f-2Sg-f-4

Table of Contents