Huawei OptiX OSN 550 Configuration Manual page 75

Multi-service cpe optical transmission system
Table of Contents

Advertisement

OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
Step 4 In the Available Conference Call Port pane, select the port where you need to configure a
conference call, and click
NOTE
Step 5 Click Apply. A dialog box is displayed, indicating that the operation is successful.
Step 6 Click Close.
Step 7 Click the General tab. Set the Conference Call number.
NOTE
Step 8 Click Apply.
----End
Example
You can follow the sample configuration to prevent a conference call loop.
Issue 02 (2011-06-30)
If the optical interfaces that support conference calls form a loop, howler tone is generated. Hence,
"releasing loop" is required, that is, only one optical port can be set for the conference calls on a certain
node.
The conference call numbers for all the NEs must be the same, and must have the same length as the
corresponding orderwire phone numbers. If the orderwire phone number has four digits, it is recommended
that you set the conference call number to 9999.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
.
2 Creating the Network
2-35