Table 13: In-Band Status Diagnostic Field Descriptions - Arris DCX3520e-M Installation Manual

High-definition
Table of Contents

Advertisement

Diagnostics
Field
Description
Mode
The values displayed on the OSD are:
64 QAM — 64 QAM digital channel
256 QAM — 256 QAM digital channel
Carrier Lock
Indicates whether the in-band receiver is locked to the carrier. If a digital carrier is not present, it indicates the
carrier is not locked:
OSD
YES
NO
PCR Lock
Indicates whether the in-band receiver is locked to the current program clock reference for a digital video
service on the specified tuner. If a digital carrier is not present, it indicates the PCR is not locked.
Data
Indicates whether data is being carried on the in-band stream. The indicators cover all packet processors
regardless of the stream they are monitoring:
OSD
YES
NO
Frequency
The in-band frequency is center RF carrier frequency tuned for the digital service on the specified tuner. The
frequency is displayed in MHz in xxxx.xxx format and ranges from 54 to 860 MHz.
SNR
When carrier lock has been established, SNR displays an estimate of the carrier signal-to-noise ratio in dB,
with an explanation:
GOOD — Good value
FAIR — Marginal signal level, check the signal
POOR — Unusable signal
INVALID — Invalid SNR value
5 Second
Indicates the number of correctable and uncorrectable digital multiplex errors, up to 9999. It is updated
every five seconds and reset each time the DCX3520e-M is power cycled or another digital multiplex is
Error
tuned. The maximum value displayed is 9999, even if there were more than 9999 errors.
Counts
High-Definition DVR DCX3520e-M • Installation Manual
365-095-25080-x.1

Table 13: In-Band Status Diagnostic Field Descriptions

Front panel
L
U
Front panel
On
Off
Description
Carrier locked
Carrier not locked
Description
In-band data detected within the
last 5 seconds
In-band data not detected within
the last 5 seconds