MAKE
GAS CONNECTION
f
1,
Connecting
gas supply to dryer
A. Flared male
fitting
____j_._
B. Non-flared
male fitting
_B
Remove red cap from flexible gas connector. Remove the
1/2" NPT adapter from the flexible gas connector (it will be
necessary to use two adjustable wrenches). Using a wrench
to tighten, connect gas supply to washer/dryer.
Use pipe-
joint compound
on threads of all non-flared male fittings.
If flexible metal tubing is used, be sure there are no kinks.
NOTE: For LP gas connections,
you must use pipe-joint
compound
resistant to action of LP gas. Do not use
TEFLON ® tape.
2,
Install
adapter
A. 1/2" rigid gas supply
pipe
B. Use pipe-joint
compound.
C.1/2" NPT adapter
D. Do not use pipe-joint
compound.
E. Flexible gas
connector
E
Install the adapter on the 1/2" rigid gas supply pipe using
pipe-joint compound.
NOTE: For LP gas connections,
you must use pipe-joint
compound
resistant to action of LP gas. Do not use
TEFLON ® tape.
3.
Attach
connector
. ofo
_
_
_
WRONG
_
CORRECT
Attach the flexible gas connector to the 1/2" NPT adapter.
Do not use pipe-joint compound for this connection.
There should be a natural loop in the flexible gas connector.
The flexible gas connector must not be twisted, kinked, or
attached with any sharp bends.
4.
Open shut-off
valve
"_
A. Closed valve
B. Open valve
Open shut-off
valve
in supply
line; valve
is open
when handle
is parallel
to gas pipe. Then,
test all connections
by brushing
on an approved
noncorrosive
leak-detection
solution.
Bubbles
will show
a leak. Correct
any leak found.
CONNECT
VENT
"1, Connect
vent to exhaust
outlet
Connecting
from front
Connecting
(for closet or recessed
from rear
area)
Using a 4" (102 mm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure vent is
clean. Dryer vent must fit over dryer exhaust outlet and inside
exhaust hood. Check that vent is secured to exhaust hood
with a 4" (102 mm) clamp.
2.
Move washer/dryer
to final
location
Move washer/dryer
to final location, taking care not to crush
or kink vent.
After washer/dryer
is in place, remove corner posts and
cardboard from under washer/dryer.