STaCkeD WaSHer/GaS Dryer GaS SuPPly

WARNING
Explosion Hazard
Use a new CSA International approved
gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified
person make sure gas pressure does
not exceed 14" (36 cm) water column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel,
and authorized service personnel.
Failure to do so can result in death,
explosion, or fire.
iMPOrTanT: Observe all governing codes
and ordinances.
This installation must conform with all local
codes and ordinances. In the absence of
local codes, installation must conform with
American National Standard, National Fuel
Gas Code ANSI Z223.1/NFPA 54 or CAN/CSA
B149.
A copy of the above code standards can be
obtained from:
National Fire Protection Association
One Batterymarch Park, Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
The design of this washer/dryer has been
certified by CSA International for use at
altitudes up to 10,000 feet (3048 m) above
sea level at the B.T.U. rating indicated on the
model/serial plate. Burner input adjustments
are not required when the washer/dryer is
operated up to this elevation.
When installed above 10,000 feet (3048 m),
a four percent (4%) reduction of the burner
B.T.U. rating shown on the model/serial
plate is required for each 1,000 foot (305 m)
increase in elevation. For assistance when
converting to other gas types and/or installing
above 10,000 feet (3048 m) elevation, contact
the local service company.