Hitachi 3080 G2 Hardware Reference Manual page 96

Hitachi nas platform
Hide thumbs Also See for 3080 G2:
Table of Contents

Advertisement

When you run the nas-preconfig script, it reconfigures the server to the
previous settings. This step allows the SMU to recognize the server as the
same and allows it to be managed. Reconfigured settings:
• IP addresses for Ethernet ports 0 and 1
• Gateway
• Domain name
• Host name
On the replacement server:
Procedure
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
96
Log in to the server.
Run the nas-preconfig script.
Reboot if you are instructed to by the script.
Log in to the SMU using one of the IP addresses you obtained.
Use a KVM (keyboard, video, and mouse) or a serial cable to connect to
the serial port on the server.
Alternatively, you can connect by way of SSH using the following
settings:
• 115,200 b/s
• 8 data bits
• 1 stop bit
• No parity
• No flow control
• VT100 emulation
Log in as root (default password: nasadmin), and enter ssc localhost
to access the BALI level command prompt.
Enter evs list to obtain the IP configuration for the server.
Using a supported browser, launch the Web Manager (SMU GUI) using
either of the IP addresses acquired from the EVS list output.
Click Yes, and log in as admin (default password: nasadmin).
Verify and, if necessary, convert the new server to the model profile
required.
This step requires a separate process, training, and license keys. Contact
Hitachi Data Systems Support Center if the incorrect model arrives for
replacement.
Navigate to Home > SMU Administration > Upgrade SMU to verify
and, if necessary, upgrade the embedded SMU to the latest SMU release.
Navigate to Home > Server Settings > Firmware Package
Management to verify and, if necessary, upgrade the new server to the
latest SU release.
Server replacement procedures