7. DIAGNOSTIC PROGRAM
7-1. Starting the Program
(1) Check that the power is turned OFF.
(2) While holding down the INIT switch, turn on the power.
(3) Release the switch when the screen below appears.
* If the switch is released before this screen appears, either of the following modes is launched.
• Power-failure recovery reboot
• INIT boot-up
(4) Enter "99990000" and press [OK].
(5) When the program is launched, the software version information is printed out as shown below.
• BOOTER
• IOC
| IOC Ver : xxxx xxxxxx
| Boot Ver : xxxx xxxxxx
(6) After the version information is displayed and printed out, a
message appears prompting for an action to take as the next
step.
To proceed with the calibration settings, press the ON/OFF
key on the display. For detailed procedures, see "[15] LCD
CALIBRATION SETTING". If you wish to skip the calibration
settings, press anywhere on the touch panel.
Power switch
Copyright(C)2008
CASIO COMPUTER CO.,LTD.
All rights reserved.
ROM VER.
xxxxxx xxxx
CREATE
xxxx-xx-xx xx:xx
QT-6600
Version
x.xx
APL VER.
xxxxxx xxxx
— 40 —
Init switch
C
7
8
9
4
5
6
1
2
3
0
OK
| IOC
| BOOTER
MAC ADRS
XX-XX-XX-XX-XX-XX
TEMP
0
VOLTAGE
0
CHARGE-MODE 359M
DISP ON/OFF
OFF
CF
NON
Ioc
Ver
: xxxxxx xxxx
Boot Ver
: xxxxxx xxxx
TOUCH START
221
Enter the Calibration mode
==>> Push Disp on/off key
Skip the Calibration mode
==>> Touch the panel
DALLAS
DRW
1CLOSE
2CLOSE
PANEL SIZE 15"
0000
00000221
Display on/off key