Cisco Aironet 350 series Quick Start Manual page 7

Hide thumbs Also See for Aironet 350 series:
Table of Contents

Advertisement

3 Associate an IP Address With the Bridge (continued)
Note IPSU can change the IP address and SSID only from their default settings. After these
values are changed, the utility cannot change them again unless you reset the configuration
to factory defaults. To do so, click Reset All System Factory Defaults on the System
Configuration Setup page in the bridge management system.
Step 1
Double-click the IPSU icon on your computer desktop to start IPSU. The following screen
appears:
Step 2
Make sure Set Parameters is selected in the Function box.
Step 3
In the Device MAC ID field, enter the MAC address as it appears on the label on the bottom
of the bridge. It should contain six pairs of hexadecimal digits. For example, your bridge's
MAC address might look like this: 00409625854c
In the IP Address field, enter the IP address to be assigned to the bridge. It should be provided
Step 4
by your system administrator.
In the SSID field, enter the case-sensitive SSID provided by your system administrator. All
Step 5
bridges in the same radio network must use the same SSID.
Note You cannot set the SSID without also setting the IP address. However, you can
set the IP address without setting the SSID.
Click the Set Parameters button.
Step 6
7