Overview/Configuration; Specification/Control/Function List; Overview - Canon i-SENSYS MF4300dn Service Manual

Table of Contents

Advertisement

8.1 Overview/Configuration

8.1.1 Specification/Control/Function List

i-SENSYS MF4300dn / i-SENSYS MF4350d / i-SENSYS MF4380dn / i-SENSYS MF4310/4318 / i-SENSYS MF4320d / i-SENSYS MF4330d / i-SENSYS
MF4340d / i-SENSYS D450d / i-SENSYS MF4370dn
Item
Fixing method
Fixing heater
Fixing temperature detection
Fixing temperature control
Protection function

8.1.2 Overview

i-SENSYS MF4300dn / i-SENSYS MF4350d / i-SENSYS MF4380dn / i-SENSYS MF4310/4318 / i-SENSYS MF4320d / i-SENSYS MF4330d / i-SENSYS
MF4340d / i-SENSYS D450d / i-SENSYS MF4370dn
The fixing unit employees the on-demand fixing method, and it is composed of fixing film unit, in which the fixing heater, thermistor, and temperature fuse are
incorporated, and the pressure roller.
The pressure roller and the delivery roller are driven with the main motor (M1).
A paper separated from the photosensitive drum is fed to inside of the fixing assembly, and the toner is fixed on a paper with the fixing film and the pressure roller.
A paper being fixed is detected with the delivery sensor (PS803); then, delivered to outside of the machine via the delivery roller.
[1] Pressure roller
[2] Fixing film
[3] Delivery roller
H1: Fixing heater
PS803: Delivery sensor
The fixing heater is the heater (ceramic heater) that the heating pattern is deposited on the ceramic plate.
By heating the fixing film with the fixing heater, it gives heat to passing papers.
The thermistor (TH1) locates at the center of the fixing heater (H1), and detects the temperature of the heater.
The temperature fuse (TP1) locates at the top center of the fixing heater. If the temperature of the fixing heater increases abnormally, it blocks power supply to the
heater by meltdown.
The temperature control of the fixing assembly composed of the foregoing components is executed at the fixing control circuit on the DCNT PCB with the instruc-
tion of the CPU (IC902). There are the fixing heater drive circuit and the fixing heater safety circuit in the fixing control circuit.
T-8-1
Function/Method
On-demand fixing
Flat heater
Thermistor (TH1): temperature control, detection of abnormality
Temperature fuse (TP1): detection of abnormality
Temperature control at startup
Temperature control at normal times
Temperature control at sheet-to-sheet interval
Temperature error detection with the thermistor
Temperature rise detection with the temperature fuse
F-8-1
Chapter 8
0020-2714
0020-2715