Troubleshooting; Backup Subsystem Cannot Be Switched On; Scsi Devices Are Not Detected; Incorrect Scsi Id - Fujitsu FibreCAT TXF Operating Manual

Backup subsystem
Table of Contents

Advertisement

5

Troubleshooting

5.1

Backup subsystem cannot be switched on

Ê Check the position of the power switch and, if necessary, move the switch to
the "Remote" or "On" position (see also
Ê Check the connections to the server and the mains connection.
Ê Boot the system unit again.
5.2

SCSI devices are not detected

If the backup subsystem is switched on late (e.g. by plugging in the power
cable), the SCSI devices may not be detected when the system unit is booted.
I
The setting „remote" can avoid that the system is switched on too late
Ê Check the mains connection.
Ê Reboot the system unit.
5.3

Incorrect SCSI ID

The backup device does not respond with demanded SCSI ID, or there is an
address conflict on the SCSI bus:
Ê Check the address jumper of the backup device involved. Refer to the
documentation for the backup device for help.
The address jumpers of most backup devices are located on the rear of the
device.
Ê Set the SCSI ID.
FibreCAT TXF
"Power switch" on page
Operating Manual
40).