Output Check (Test Mode 03) - Toshiba e-studio600 Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-studio600:
Table of Contents

Advertisement

2.2.2

Output check (test mode 03)

Status of the output signals can be checked by keying in the following codes in the test mode 03.
<Operation procedure>
Procedure 1
[0][3]
(Code)
[START]
[POWER]
Procedure 2
[0][3]
(Code)
[POWER]
Procedure 3
[0][3]
(Code)
[START]
[POWER]
Procedure 4
[0][3]
[POWER]
March 2005 © TOSHIBA TEC
Operation
Stop
ON
code
Operation
[START]
One direction
Operation
[START]
ON
(Code)
e-STUDIO520/600/720/850 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 35
Operation
[START]
OFF
Test mode
[CLEAR]
standby
Operation
[CLEAR]
OFF
[POWER] OFF
[START]
[POWER] OFF/ON
(Exit)
[POWER] OFF/ON
(Exit)
[POWER]
Test mode
OFF/ON
standby
(Exit)
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio720E-studio850E-studio520

Table of Contents