PROBLEM
Camera video image not
seen.
Flashing Battery Warning
appears.
Trade Tool is an Authorized Service Centr and a Ridgid Pro Platinum distributor
www.tradetoolsupply.com
503.221.8665
Rental units available
16
DVD Pak
®
PROBABLE FAULT LOCATION
No power to SeeSnake.
Connections faulty.
Display set to wrong source.
Batteries Low.
DVD Pak 18 V batteries low.
Check power is correctly plugged in or battery is
charged.
Check switch on on DVD Pak .
Check SeeSnake System Cable connections to
DVD Pak and reel.
Check seating, and pins in SeeSnake connection.
Set-up as described in Video Display Set-up.
Recharge batteries or connect external power sup-
ply.
Recharge DVD Pak batteries. Switch to AC power
(110/220VAC).