Troubleshooting
Guide (cont'd)
Operational
Conditions
(cont'd)
"AIR"
IN HOT
WATER
FAUCETS
NOT
ENOUGH
OR NO
HOT
WATER
AWARNING
HYDROGEN
GAS: Hydrogen gas can be produced in a hot
water system that has not been used for a long period of time i
(generally two weeks or more). Hydrogen gas is extremely I
flammable and explosive. To prevent the possibility of injury
under these conditions, we recommend
the hot water faucet
be opened for several minutes at the kitchen sink before any
electrical appliances which are connected to the hot water sys-
tem are used (such as a dishwasher or washing machine). If
hydrogen gas is present, there will probably be an unusual
sound similar to air escaping through the pipe as the hot water
faucet is opened. There must be no smoking or open flame
near the faucet at the time it is open.
VENTING
MANUAL
RESET
SWITCH
There
is a venting
manual
reset switch located
on the draft
hood. If the switch is activ_ed,
it will not reset itself. Before
resetting
this switch, check for flue blockage and propriety of the
venting system. To reset the venting manual reset switch, press
the redreset
button.
: Check the manual gas shut offvalve m be sure it is open.
Check the pilot flame. It may have gone ont. All models have
an opening behind tile outer door fiatviewing the pilot.
If the pilot is not lit, fbllow the 'q.ighting" instructions in this
manual or located above the gas control valve on the water
heater to relight the pilot. If the water was extremely hot and is
now cold, tbe high limit safety temperature shut off may have
put out the burner and pilot. If the high temperature shut off
activates, the gas control valve must be replaced. Contact the
Sears Service Center.
°. The gas control knob must be turned to the "ON" position.
" The temperature adjustment dial may be set too low. See the
"Temperature Regulation" section.
, The gas company can check the gas input to see if it is correct.
An underfired water heater will not heat water as quickly.
• Look for leaking or open hot water faucets. Make sure all are
closed.
• The cold water inlet temperature may he colder during the win-
ter months. It will take longer to heat the water and seem like
less hot water.
• If'you cannot find what is wrong, call the Sears SetMce Center.
RESETSWITCH
BLOWER MOTOR
WATER
IS TOO HOT
1. The temperature adjustment dial nlay be set too high. See the
"Temperature Adjustment" section.
NOTE: A period of time is necessary after an adjustment has
been made for the water temperature to reach the new tem-
perature setting.
2. If lower temperature settings will not lower the water tempera-
ture, call the Sears Service Center.
DRAFT
HOOD
HIGH
TEMPERATURE
SHUT
OFF SYSTEM
This water heater is equipped with an automatic gas shut offsys-
tern. The high temperature shut off is built into the gas control
valve. This system shuts off the gas supply to the water heater
burners when high water temperatures
are present. It is non-
resettable. If the high temperature shut off activates, the gas con-
trol valve must he replace& If this were to occur, turn "OFF" the
entire gas supply to the water heater. Contact the Sears Service
Center.
AWARNING
Due to the nature
of the typical gas water heater, the
water temperature
in certain situations may be hotter
than the thermostat
setting.,
Short, frequent draws of hot water - especially with very
cold incoming water - can shock the thermostat
into brief
operation
resulting in hotter and hotter
layers of water
closer to the top of the tank.
Changes in hot water usage patterns or raising the tem-
perature
differential
between the cut-on of the thermo-
stat and the cold water temperature
will usually eliminate
the problem.
AWARNING