11
DCCC Junction Box
Purpose:
The DC Charge Controller junction box is the interface between the turbine and the
DC Charge Controller which includes the dump load, turbine ON/OFF switch and
anemometer. The DC Charge Controller uses the dump load to put the turbine in STOP
mode when there is a fault, a user has pressed the STOP key, or when the generator
voltage exceeds 165VDC. When the voltage decreases, the brake is released. The
turbine ON/OFF switch will put the turbine in a hard STOP mode whether or not the
dump load is connected. It also disconnects the turbine from the DC Charge Controller.
Mounting:
The junction box comes hard wired to the turbine. It should be mounted to ensure the
anemometer will be able to function through all seasons (i.e. will not be covered with
snow in the winter). The junction box can be mounted through two pre-drilled holes
tapped for 5/16"-18 bolts in the black mounting bars on the back of the junction box.
The QUADPOD Mount has pre-drilled holes for mounting of the junction box. Mounting
hardware is supplied by the Installer.