Connecting The Assembly Cable; Installing And Connecting The Indoor Unit Drain Hose; To Install The Drain Hose - Samsung AQ07A1VE Service Manual

Room air conditioner
Hide thumbs Also See for AQ07A1VE:
Table of Contents

Advertisement

3-2-2(c) Connecting the Assembly Cable.
Indoor unit
1(N) 2
3
4
5
1
2
3
4
5
Out door unit
A
B
C
D
E
YAB(X)
■ ✳✳
Indoor unit
N1 1
2
3
E
1
2
3
4
5
Out door unit
A
B
C
D
E
To install the drain hose, proceed as follows.
1. If necessary, connect the 2-metre extension to the drain hose.
2. If you are using the extension, insulate the inside part of the extension drain hose with a shield.
3. Pass the drain hose under the refrigerant piping, taking care to keep the drain hose tight.
4. Pass the drain hose through the hole in the wall, making sure that it is sloping downwards, as
shown in the illustrations above.
Shield
Drain hose
Extension drain hose
Samsung Electronics
The outdoor unit is powered from the indoor unit via the assembly
cable. If the outdoor unit is more than five metres away from the
indoor unit, the cable must first be extended to a maximum of ten
metres.
1. Extend the assembly cable if necessary.
2. Open the front grille by pulling on the tabs on the lower right and
left sides of the indoor unit.
3. Remove the screw securing the connector cover.
4. Pass the assembly cable through the rear of the indoor unit and
connect the assembly cable to terminals 1(N) to 5.
• Each wire is labelled with the corresponding terminal number.
5. Firmly fix the ass'y cable with clamp wire holder.
6. Pass the other end of the cable through the 65mm hole in the wall.
7. Replace the connector cover, carefully tightening the screw.
8. Close the front grille.
9. For further details on how to plug the other end of the assembly
cable into the outdoor unit, refer to page 3-8.
3-2-2(d) Installing and Connecting the Indoor Unit Drain Hose
Care must be taken when installing the drain hose for the indoor unit
to ensure that any condensation water is correctly drained outside.l
When passing the drain hose through the 65mm hole drilled in the
wall, check that none of the following situations occur.
The hose must
The end of the
NOT slope upw
drain hose must
ards.
NOT be placed in
water.
The hose will be fixed permanently into position once
the whole installation has been tested for gas leaks;
Operating Instructions and Installation
Do NOT bend the
Keep a clearance
hose in different
of at least 5cm
directions.
between the end
of the hose and
the ground.
5cm
less
Do NOT place the
end of the drain
hose in a hollow.
3-7