2. Specifications
2.1 Specifications for outdoor units
Item
Function
Capacity
Capacity
Total power input
Max. power input
EER or COP
Energy efficiency stage
Dehumidifying capacity
Power cable
Power source
Running /Max.Running current
Start Current
Unit model (color)
Compressor
Fan
Heat exchanger
Dimension
Drainage pipe (material , I.D./O.D.)
Refrigerant control method
Defrosting
Volume of Accumulator
Noise level
Type of Four way valve
material of reduce noise
crankcase heater power
Weight
(Net / Shipping)
Refrigerant
Pipe
Connecting Method
Between I.D &O.D
Norminal condition: indoor temperature (cooling): 27℃DB/19℃WB, indoor temperature (heating): 20℃DB
Outdoor temperature(cooling): 35℃DB/24℃WB, outdoor temperature(heating): 7℃DB/6℃WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound
intensity meter. It is a sound pressure noise level.
Model / Manufacture
Type
Type × Number
Speed
Fan motor output power
Air-flow(H-M-L)
Type / Diameter
Total area
Temp. scope
External
(L×W×H)
Package
(L×W×H)
Type / Charge
Recharge quantity
Liquid
Gas
MAX.Drop
MAX.Piping length
>a__WcU[S^ <[c >a`V[e[a`Wc
Model
Cooling
9000
BTU/h
2700
W
1080
W
2000
W
2.5
W/W
E
10‐³×m³/h
H07RN-F3G X2.5mm
1PH~
N, V, Hz
6.5/10.5
A / A
A
C-6RB137H03AA / SANYO
r/min
kW
m³/h
mm
m²
℃
mm×mm×mm
mm×mm×mm
mm
mm/mm
L
dB(A)
W
kg / kg
g
g/m
mm
mm
m
m
-8-
AU092AABHA
Heating
11000
3000
1230
1900
2.44
G
/
2
220V-230V
50Hz
7/10
45
WHITE
Rotary
Axial-flow
670±30
0.35
1600
TP2M/9.52
0.65
43-60
780*250*640
907*344*690
/
Capiliary 1.8*170
auto
1
49/—/—
DPF-6
XPE
/
40/45
R407C
2200
30
6.35
12.7
Flared
20
30