T8602D CHRONOTHERM
Installer Setup
Number (Press
Time ∆ key to
Select
change)
Not Used.
a
Fan operation
Not Used.
Heating cycle
rate.
Not Used.
5 thru 11
System setting
adjustment
Adaptive
Intelligent
Recovery™
control.
Degree
temperature
display
Not Used.
Clock format.
Not Used.
17 and 18
Extended fan
operation in
a
heating.
Extended fan
operation in
a
cooling.
Not Used.
21 thru 23
Outdoor
temperature
display (models
with OT
terminals).
Not Used.
25 thru 29
Deadband
Not Used.
31 thru 32
69-1507—2
®
IV DELUXE PROGRAMMABLE THERMOSTATS
Table 3. Thermostat Installer Setup Options.
Factory Setting
Display
1
2
0
Conventional
applications where
equipment controls
fan operation in
heat mode
3
4
6
6—6 cph used for
conventional heat
12
1
Manual
changeover
13
0
Adaptive Intelligent
Recovery™
control is activated
(system starts
early so setpoint is
reached by start of
program period).
14
0
Temperature is
displayed in °F
15
16
0
12-hour clock
format.
19
0
No extended fan
operation after the
call for heat ends.
20
No extended fan
operation after the
call for cool ends.
24
0
No outdoor
temperature is
displayed.
30
3
Heating and
cooling setpoints
can be set no
closer than 3°F
(1.5°C).
(Press
Description
Display
1
1, 3 or 9 1—1 cph used for radiant
0 or 2
1
1
1
1
1
1
4 thru 10
6
Other Choices
or
key to change)
Description
Heat pump or electric heat
applications where
thermostat controls fan
operation in heat mode.
floor heat, gravity system
3—3 cph used for hot water
systems or high
efficiency furnaces
9—9 cph used for electric
heat systems
0—Auto changeover
2—Auto only
Conventional recovery
(system starts recovery at
programmed time).
Temperature is displayed
in °C
24-hour clock format.
Fan operation is extended
90 seconds after the call for
heat ends.
Fan operation is extended
90 seconds after the call for
cool ends.
Outdoor temperature is
displayed. Needs a
C7089B1000 Outdoor
Temperature Sensor to
operate.
Heating and cooling
setpoints can be set no
closer than the chosen
value:
4—4°F (2°C)
5—5°F (2.5°C)
6—6°F (3°C)
7—7°F (3.5°C)
8—8°F (4°C)
9—9°F (4.5°C)
10—10°F (5°C)
Actual
Setting