<DC-CON (3/7)>
Address bit
Notation
P010
0
M5
1
M5
2
M5
3
M5
4
M5
5
M5
6
M5
7
M5
8
M5
9
10
11
12
13
14
15
P011
0
M7B
1
M7B
2
M7B
3
M7B
4
M7B
5
M7B
6
M7B
7
M7B
8
M7B
9
10
11
12
13
14
15
P012
0
1
2
3
4
5
6
7
Description
delivery motor pulse signal A_D0
delivery motor pulse signal A_D1
delivery motor pulse signal A_D2
delivery motor pulse signal A_PHASE
delivery motor pulse signal B_D0
delivery motor pulse signal B_D1
delivery motor pulse signal B_D2
delivery motor pulse signal B_PHASE
delivery motor pulse signal I0
not used
not used
not used
not used
not used
not used
not used
2-way delivery inlet motor pulse signal A_D0
2-way delivery inlet motor pulse signal A_D1
2-way delivery inlet motor pulse signal A_D2
2-way delivery inlet motor pulse signal A_PHASE
2-way delivery inlet motor pulse signal A_D0
2-way delivery inlet motor pulse signal A_D1
2-way delivery inlet motor pulse signal A_D2
2-way delivery inlet motor pulse signal lA_PHASE
2-way delivery inlet motor pulse signal I0
not used
not used
not used
not used
not used
not used
not used
laser output enable signal
printer output prepare signal
transmission ready signal
scanner start signal
optional output signal 0
optional output signal 1
optional output signal 2
optional output signal 3
CHAPTER 5 SERVICE MODE
COPIER>I/O>DC-CON
Remarks
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0: enabled
-
-
-
-
-
-
-
5-23