Electrical connection

,
All electrical work must be performed by a
qualified service technician in accordance with
applicable codes and standards.
When installaing a residual current device (RCD) a
Type B GFCI circuit breaker must be installed.
The connecting terminal is located behind a cover.
The machine must only be connected to the voltage
and frequency shown on the data plate.
The machine is equipped with a multi-tap
transformer.
Steam heated washers are factory set to
3 phase, 208 V, 60 Hz
They can be converted to
3 phase, 240 V, 60 Hz by a Miele Service Technician.
Electrically heated washers are factory set to 3
phase, 230 V, 50/60 Hz
They can be converted to
3 phase, 208 V, 60 Hz by a Miele Service Technician.
Equalizer
Secure the potential equalizer, if necessary.
To activate the heating the water level in the drum
5
must be 4
/
" (110 mm) high.
16
A motor overload protection is located in the motor
winding.
See the enclosed wiring and installation diagrams.
Installation Instructions
Steam connection
The steam connection must only be connected by a
certified installer. For more information see the
enclosed installation plan and the installation manual.
Connecting the dispensing pumps
The connecting terminal for 4 time controlled
dispensing pumps is located behind the cover next to
the electrical connection. See the supplied wiring
diagram.
The dispensing pumps can be operated without the
multifunction module.