Programming the Control Panel

Setup Considerations

Cameras connected to the V4000 can be triggered by system events from a Honeywell
Vista control panel.
The cameras are turned on using Output (relay) Programming commands in the
control panel, although no relay module is actually used. To accomplish this, do the
following:
1.
Enable a 4204 Relay Module in the system's Device Programming Mode as
Device Address 12.
2.
Program up to four logical relays to be triggered by different alarm conditions
you would like to turn cameras on with, and program each to "pulse for 2
seconds" when triggered. Cameras are turned on through the ECP (Data In
and Data Out) connections (see the control panel's Programming Guide for
information on how to program output relays).
3.
Program Relay 4 to trip upon "kissoff" of the control panel's message to the
central station. This relay will cause the V4000 to call the central station
number programmed inside of it and transmit the video information of the
triggered output's camera.
IMPORTANT: If four actual cameras are desired, one of the first three relays
must be programmed to trigger on two different events (two "logical" outputs
which point to the same "physical" relay must be programmed). One of those
outputs must be programmed to "continuous pulse" when it turns on, so that
the V4000 can differentiate between the messages. See the example below.
4204 Output Command (4204 on ECP Address 12)
Relay 1: Turn ON for 2 seconds when zone 1 goes into alarm
Relay 2: Turn ON for 2 seconds when zone 4 goes into alarm
Relay 3: Turn ON for 2 seconds when system is disarmed
Relay 1: Continuous Pulse when zone 8 goes into alarm
Relay 4: Turn ON for 2 seconds upon kissoff from central station
Notes: The linking of outputs to specific cameras is performed by Control Center
Software'.
Only conditions that cause a central station report to be sent can be used to
trigger camera transmissions (e.g., alarms).

Control Center Software Installation

Minimum System Requirements

• CPU: Intel Pentium III 800 MHZ or higher processor.
• Memory: 128MB of RAM
• Free Space: 5MB of available hard disk space.
• Modem: 33.6/56K
• Operating System: Windows 98/ME/2000 professional/ NT4/XP.
• Minimum screen resolution: 800X600, 24 true-bit colors
Causes V4000 to dial out to video central
9
Function
Captures Video on Camera 1
Captures Video on Camera 2
Captures Video on Camera 3
Captures Video on Camera 4
station