5.2 CPU Peripheral Circuit
5.2.1 PC-8201 Power Supply Operation Test
(
Reference
)
Chaptcr 4 DISASSEMBLY/REASSEMBLY
( I ) Measured power supply
PIN No. 3
-5 V
PIN No. 6
5 V
(within +lo% to -5%)
*
If power supply operation is abnormal. see Item 6.2.1 "PC-89-01 Abnormal
Power Supply".
5.2.2 Reset Operation Test
AS soon as the power supply is turned o n o r reset is depressed, the RESET signal in U17,
80C85, (P36) changes from "H" level t o "L" level and the RESET O U T signal in
U17
(P3)
changes from "L" level t o "H" level.
Figure 5.1 Reset Operating
Test
*
If reset is abnormal. see Item 6.2.9- "PC-8301 Abnormal Reset"