Kenwood NX-800H Service Manual page 56

Hide thumbs Also See for NX-800H:
Table of Contents

Advertisement

NX-800/800H
Item
Panel test mode
10. LTR
1) Adj item: [An LTR]
Deviation
Adjust: [✳✳✳✳]
adjust *4
Deviation meter
LPF: 3kHz
[Narrow]
HPF: OFF
PTT: ON
Press [ ] key to store
the adjustment value.
[Wide]
1) Adj item: [Aw LTR]
Adjust: [✳✳✳✳]
PTT: ON
Press [ ] key to store
the adjustment value.
11. DTMF
1) Adj item: [An DTMF]
Deviation
Adjust: [✳✳✳✳]
adjust *4
Deviation meter
LPF: 15kHz
[Narrow]
HPF: OFF
PTT: ON
Press [ ] key to store
the adjustment value.
[Wide]
1) Adj item: [Aw DTMF]
Adjust: [✳✳✳✳]
PTT: ON
Press [ ] key to store
the adjustment value.
12. Single
1) Adj item: [An TONE]
Tone
Adjust: [✳✳✳✳]
Deviation
Deviation meter
(2TONE
LPF: 15kHz
deviation
HPF: OFF
adjust)
PTT: ON
adjust *4
Press [ ] key to store
the adjustment value.
[Narrow]
[Wide]
1) Adj item: [Aw TONE]
Adjust: [✳✳✳✳]
PTT: ON
Press [ ] key to store
the adjustment value.
13. MSK
1) Adj item: [An MSK]
Deviation
Adjust: [✳✳✳✳]
adjust *4
Deviation meter
LPF: 15kHz
[Narrow]
HPF: OFF
PTT: ON
Press [ ] key to store
the adjustment value.
56
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item: [LTR
Deviation
Deviation (Narrow)]
meter
Deviation meter
Oscilloscope
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply]
button to store the
adjustment value.
1) Adj item: [LTR
Deviation (Wide)]
PTT: Press
[Transmit] button.
Press [Apply]
button to store the
adjustment value.
1) Adj item: [DTMF
Deviation (Narrow)]
Deviation meter
LPF: 15kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply]
button to store the
adjustment value.
1) Adj item: [DTMF
Deviation (Wide)]
PTT: Press
[Transmit] button.
Press [Apply]
button to store the
adjustment value.
1) Adj item: [Single Tone
Deviation (Narrow)]
Deviation meter
LPF: 15kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply]
button to store the
adjustment value.
1) Adj item: [Single
Tone Deviation (Wide)]
PTT: Press
[Transmit] button.
Press [Apply]
button to store the
adjustment value.
1) Adj item: [MSK
Deviation (Narrow)]
Deviation meter
LPF: 15kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply]
button to store the
adjustment value.
Measurement
Test-
Unit Terminal Unit
ANT
Adjustment
Specifi cations /
Parts
Method
[Panel
Write the value as
0.65~0.85kHz
tuning
followings.
mode]
465 (Reference
[ ],[ ]
value)
[PC test
mode]
[ ],[ ]
0.90~1.10kHz
Write the value as
1.40~1.60kHz
followings.
650 (Reference
value)
2.90~3.10kHz
Write the value as
1.40~1.60kHz
followings.
513 (Reference
value)
2.90~3.10kHz
Write the value as
1.40~1.60kHz
followings.
513 (Reference
value)
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nx-800

Table of Contents