Entry Delay Example; Extended Delay; Exit Extension; No Delay-For Instant Alarm - GE Security Pro 500 User Instructions

Ge security pro 500
Table of Contents

Advertisement

Note
In UL Listed systems, this
feature is disabled.
Note
The Exit Extension will work
on the first re-entry only.
7
The interior sirens and touchpads sound three quick status beeps, telling you that the system
accepted the command and has started the Exit Delay time.
During the Exit Delay time, the system sounds one short beep every 4 seconds. The red ARMED
indicator light on fixed display touchpads will flash. During the last seconds of the delay time,
the beeps will accelerate to one per second. Exit the premises immediately.
At the end of the Exit Delay, you'll hear three more quick status beeps. These beeps indicate that
the Exit Delay has ended. The ARMED indicator light on fixed display touchpads will stop flash-
ing and remain on. Opening an armed door or window after the Exit Delay has expired will cause
an alarm.
A f t e r a r m i n g ,
y o u ' l l h e a r
3 q u i c k
s t a t u s b e e p s .

Entry Delay Example

You are returning to your house that is armed to Level 3—AWAY. When you unlock and enter
the designated delay door, the interior sirens and touchpads sound two short beeps every two sec-
onds. The red ARMED indicator light on fixed display touchpads will flash. This tells you that
the Entry Delay time has begun and reminds you to disarm the system to avoid setting off an
alarm.
During the last 10 seconds of Entry Delay, you'll hear two short beeps every second.
U p o n e n t e r i n g , d u r i n g t h e
E n t r y D e l a y , y o u ' l l h e a r 2 b e e p s
e v e r y 2 s e c o n d s .
Your installer will work with you to decide which door(s) should be delay door(s), and determine
the delay times that will work best for you and your family. Then, the installer will program the
Exit and Entry Delay times into your system.

Extended Delay

In some situations, additional time is needed to arm or disarm the system from, for example, a
protected outside gate or door. In these instances, the installer can program an extended delay,
giving as much as 16 minutes to exit or disarm the system before setting off an alarm.
Refer to the Appendix A User Sheets, "Delay Doors and Delay Time Settings," for a list of actual
exit delay times.

Exit Extension

Your system may be set up so that the exit delay time is restarted if you reopen the delay door
during the initial exit delay time.
This is useful if, after arming the system, you walk out the door, then remember something you
forgot inside. You can reenter and exit through the delay door without disarming and rearming
the system.
If your system is not using this feature, you must disarm the system when you reenter the armed
premises to avoid setting off an alarm.
No Delay—For Instant Alarm
You can choose to turn off the Entry and Exit Delays, causing the delay doors to arm immedi-
ately. Anyone entering the house through the delay door when the system is set to No Delay
would immediately cause an alarm.
No Delay is normally used:
When you're staying at home, after you've armed the system.
When you're arming and disarming your house from the outside. (You must have a wireless
touchpad in order to do this.)
B
E
E
P
S
D u r i n g t h e E x i t D e l a y ,
3 q u i c k s t a t u s
y o u ' l l h e a r o n e b e e p e v e r y
b e e p s s o u n d
f o u r s e c o n d s .
b e f o r e t h e s y s t e m
L e a v e t h e p r e m i s e s n o w .
i s a r m e d .
B
E
E
P
S
D i s a r m
t h e s y s t e m
t h e l a s t o f 1 0 q u i c k s t a t u s b e e p s
t o a v o i d a n a c c i d e n t a l a l a r m .