Aperture Dimensions And Ventilation Requirements - Baumatic BRB2713.5 User Manual

264 litre built-in combi fridge-freezer
Table of Contents

Advertisement

o If either seal is not adhering to the cabinet properly, then you
should either:-
1. Use a warm damp cloth and manipulate the seal until it does
adhere to the cabinet properly, all the way around the door.
or
2. Use a hair dryer on its lowest heat setting and lightly heat the
areas of the door seal that are not adhering correctly. The
heat will make the seal more pliable and this will allow you to
manipulate the seal into the correct position.
IMPORTANT: DO NOT HEAT THE DOOR SEAL ON ANYTHING BUT
THE LOWEST HEAT SETTING, OR HEAT THE SEAL FOR A LONG
PERIOD OF TIME. OTHERWISE DAMAGE MAY BE CAUSED TO
THE DOOR SEAL, WHICH WOULD NOT BE RECTIFIED UNDER
THE GUARANTEE FREE OF CHARGE.
IMPORTANT: WHEN YOU HAVE REVERSED THE DOORS OF THE
APPLIANCE. AS YOU HAVE PLACED THE APPLIANCE ON ITS
SIDE, YOU MUST WAIT FOR 8 HOURS BEFORE SWITCHING THE
APPLIANCE BACK ON.

Aperture dimensions and ventilation requirements

The appliance aperture should be:
Height-
1776-1782 mm
Width-
560 mm
Depth-
570 mm
31